Omron E2 ELITE Instruction Manual

Omron E2 ELITE Instruction Manual

Electronic nerve stimulator
Hide thumbs Also See for E2 ELITE:

Advertisement

Electronic Nerve Stimulator
E2 ELITE
(HV-F127-E)
• Instruction Manual
• Mode d'emploi
• Gebrauchsanweisung
• Manuale di istruzioni
• Manual de instrucciones
• Gebruiksaanwijzing
IM-HV-F127-E-04-06/2010
1647391-4D
EN
FR
DE
IT
ES
NL

Advertisement

Table of Contents
loading

Summary of Contents for Omron E2 ELITE

  • Page 1 Electronic Nerve Stimulator E2 ELITE (HV-F127-E) • Instruction Manual • Mode d’emploi • Gebrauchsanweisung • Manuale di istruzioni • Manual de instrucciones • Gebruiksaanwijzing IM-HV-F127-E-04-06/2010 1647391-4D...
  • Page 2: Table Of Contents

    2.5 How to treat....10 Treat with the Quick Relief button . . . 12  Thank you for purchasing the OMRON Electronic Nerve Treat with the Region button ..12 Stimulator E2 ELITE (HV-F127-E).
  • Page 3: Before Using The Unit

    1.Before using the unit 1. Before using the unit 1.1 Notes on safety (Please read this section carefully before using the unit.) The icons and warning signs are indicated here for your Do not use this unit for purposes other than treat- ment indicated in this manual.
  • Page 4: General Information On Omron E2 Elite Electronic Nerve Stimulator

    1.Before using the unit General information on OMRON E2 ELITE Electronic Nerve Stimulator The OMRON E2 ELITE Electronic Nerve Stimulator Our nerves, which radiate throughout the entire body as a complex network, perform various tasks which are indispens- is an electro-therapeutic device.
  • Page 5: Package Contents

    1.Before using the unit 1.5 Package contents The following components are included in the box. If any components are missing, please contact the nearest OMRON dealer. Main unit Electrode Cord Electrode Holder Soft fabric pouch Long-Life Pad (to be referred to as “Pad”...
  • Page 6: Names And Functions Of The Parts

    1.Before using the unit 1.7 Names and functions of the parts Main Unit Electrode Cord Connects the Main unit with the Pad Electrode Cord Plug Intensity Adjustment Dial/Power Button Turns on and off the power Electrode and adjusts the intensity of Cord Jack stimulation.
  • Page 7 1.Before using the unit Electrode Cord Plug Attach the red or the white plug to each Pad. Tab of the Pad Hold the Tab to peel off the Pad. Point & Wide Mode Balance Adjustment (Switching between red and white buttons) Point The unit treats the red and the R-button...
  • Page 8: How To Use The Device

    Pads irrespec- General advice from OMRON on the handling of Electrode Cord tive of color. • Avoid excessive bending and pulling of the Electrode Cord.
  • Page 9: How To Attach The Electrode Pads

    7 seconds. the Pads. As the Pads have strong adhesive- General Advice from OMRON on the handling of Pads ness, peel off the clear plastic film from the Pads and attach the Pads • Do not place pads stacked on each other.
  • Page 10: How To Treat

    2.How to use the device Calf Waist (Lower Back) Swelling and fatigue of the Calf is presumably caused by con- Back pain is caused by various reasons. The type of back pain gestion of blood and accumulation of fatigue substances in that can be treated by low-frequency therapy includes stiffness that region.
  • Page 11 2.How to use the device Adjust the intensity of When the treatment stimulation. ends, turn power. Select your favorite intensity level from 1 Rotate the Intensity to 10 by rotating the Dial/Power Button Intensity Dial/Power upwards. When you Button. hear a click, the power is turned off.
  • Page 12: Treat With The Quick Relief Button

    2.How to use the device How to treat Treat an area by selecting one of the programmes within Relief, Region or Massage Treat an area with the button Treat an area with the button When you want to relieve severe acute pain promptly When you want to relieve severe acute pain promptly Push the Quick Relief Push the Region Button.
  • Page 13: Treat With The Massage Button

    2.How to use the device How to treat Treat an area by selecting one of the programmes within Relief, Region or Massage Treat an area with the button When you want to treat an area according to your symp- tom and favourite operation by selecting the massage method from Tapping, Kneading, Pushing, and Rubbing Push the Massage (M) Button.
  • Page 14: After Treatment - Storing The Unit

    2.How to use the device 2.6 After treatment – storing the unit When the Pads are poorly maintained, they will become Lightly attach the Pads to dirty or the adhesiveness will deteriorate. When the the Electrode Holder. treatment ends, attach the Pads to the Electrode Holder * You may leave the Elec- and store them.
  • Page 15: Maintenance

    (Refer to page 14.) slow running cold water for several seconds. General advice from OMRON on the handling of Pads • Do not use hot water, detergent, or chemicals such as thinner or benzine. • Do not scratch the adhesive surface with your nail or a brush.
  • Page 16: Troubleshooting

     The adhesive surface of the pads is dirty or irritated. dry.  Replace the pads with new ones.  The adhesive surface of the pads is damaged. * If the unit does not operate after taking the above-mentioned measures, contact the nearest OMRON dealer.
  • Page 17 Recommendation is to keep a minimum distance of 7 m. Verify correct operation of the device in case the distance is shorter. Further documentation in accordance with EN60601-1-2:2007 is available at OMRON Healthcare Europe at the address mentioned in this instruction manual. Documentation is also available at www.omron-healthcare.com.
  • Page 18: Specifications

    * In the interest of product improvement, specifications are subject to change without notice. * This device fulfils the provisions of the EC directive 93/42/EEC (Medical Device Directive). * This OMRON product is produced under the strict quality system of OMRON HEALTHCARE Co., Ltd., Japan. Available accessories / replacement parts: 1.