Dyson AM10 Operating Manual

Dyson AM10 Operating Manual

Dyson am10 humidifier
Hide thumbs Also See for AM10:

Advertisement

Operating Manual
Important!
Weekly and
monthly cleaning
required.
Register
Your free 2 year
guarantee today.

Advertisement

Table of Contents
loading

Summary of Contents for Dyson AM10

  • Page 1 Operating Manual Important! Weekly and monthly cleaning required. Register Your free 2 year guarantee today.
  • Page 2: Important Safety Instructions

    16. Do not unplug by pulling on the cable. To unplug, grasp the plug, not the cable. 5. Use only as described in this Dyson Operating Manual. Do not carry out any maintenance 17. Do not stretch the cable or place the other than that shown in this manual, or cable under strain.
  • Page 3: Important Safety Features

    23. When refilling, only do so as described in this automatic cut-out switches that operate if it tips over. If the switches operate, unplug the Dyson operating manual. Do not use hot water. appliance. Before restarting, check and clear 24. Always place the appliance on a firm, flat, any blockages, allow to dry and ensure the level surface.
  • Page 4: Year Guarantee

    Register by mail Alternatively, visit www.dyson.co.uk/support (UK) or www.dyson.ie/ Complete and return the form to Dyson in the envelope supplied. support (ROI) for online help, general tips and useful information about Dyson. Dyson contact details UK: Website: www.dyson.co.uk/support...
  • Page 5: Know Your Humidifier

    Know your humidifier Remote control Loop Handle Chimney Seal Tank Loop release button Base Inlet Piezo UV-C emitter LED display On/ off button Plug...
  • Page 6: Getting Started

    Getting started For the best performance place humidifier on the floor in the corner of the room, facing into the centre. It should be at least 1m from any wall. To avoid a cooling effect while humidifying, the unit should be at least 1m from any people.
  • Page 7 Plug into the socket and base. A small Switch ‘ON’. The water treatment After 3 minutes the appliance will start blue LED on the back of the appliance procedure automatically starts. to humidify. The display will show the lights up to confirm that the appliance Water passes over a UV-C emitter to target humidity setting.
  • Page 8: How To Use

    How to use Fan/ humidity toggle ON/ OFF switches between humidifier and fan modes. Control with airflow and timer buttons. On/off Controlling the humidity manually Airflow Increase airflow. Increase target humidity. 1 to 10 30 to 70% Decrease airflow. Decrease target humidity. 10 to 1 70 to 30% The appliance will not mist...
  • Page 9: Refilling The Tank

    Blue light indicates that the AM10 is in humidity mode. White light indicates that the AM10 is in fan mode. Switch ‘ON’: the water treatment procedure starts. After 3 minutes the appliance will start to humidify.
  • Page 10: Cleaning Solution

    Cleaning – important! Cleaning procedures must be routinely followed to ensure that the humidifier continues to operate efficiently. Cleaning regimes are designed to help prevent the build up of scale within the machine, which will be more prominent in hard water areas. Failure to adhere to the cleaning regimes may invalidate the warranty.
  • Page 11: Once A Week Cleaning

    Once a week Wipe over air loop amplifier, paying Turn the appliance into standby mode/‘OFF’. close attention to the air gaps. Wipe with a lint-free microfibre cloth. Unplug from the mains electricity supply. Empty the water. Rinse and wipe over all surfaces.
  • Page 12: Once A Month Cleaning

    Once a month (and before/after storage) Unclip the loop amplifier surround: pull from the lower Turn the appliance into standby mode/‘OFF’. Unplug from the mains electricity supply. edge by hand, gently but firmly. 15 mins Empty the water tank. To release the water chimney, twist the dial a quarter of a turn.
  • Page 13 Some cleaning chemicals are harmful to the appliance and should not be used. Use of these will invalidate your guarantee. Do not use: Alcohol and strong acid mixes, solvent (acetone) and oil based products, alkali bleach mixes, air fresheners, aroma oils, scented oils, hot water, brushes, abrasive materials, etc.
  • Page 14: Lights & Indicators

    What do the lights mean? Water treatment The AM10 is treating the water. This takes 3 minutes. When the animation stops, the AM10 will start to humidify. Tank is empty Switch ‘OFF’ and refill. Tilted The base is not level.
  • Page 15: Using Your Humidifier

    Using your humidifier Please read the ‘Important Safety Instructions’ in this Dyson Operating appliance will switch itself ‘ON’ or ‘OFF’ as necessary to maintain Manual before proceeding. that level. The fan will remain running when the target humidity has been reached.
  • Page 16: Disposal Information

    • Complete the enclosed form and post it to us. CAUTION This will confirm ownership of your Dyson appliance in the event of an • Unscrew the battery compartment on the remote control. Loosen insurance loss, and enable us to contact you if necessary.
  • Page 18 JN.71733 PN.302491-02-03 09.01.15...
  • Page 20: Guarantee Form

    Telephone Mobile As a Dyson fan owner, you can hear about Dyson We sometimes ask other companies (such as market researchers) to inventions, services and products before anyone else. contact owners on our behalf. We do this to get feedback on ideas or If it’s okay to contact you, please let us know how we...