WARNING:
A. This appliance is equipped with an ignition device
which automatically lights the pilot. Do not try to light
the pilot by hand.
B.
BEFORE OPERATING
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
1. STOP! Read the safety information above on this label.
2. Set the thermostat to lowest setting.
3. Turn off all electric power to the appliance.
MAIN POWER
ROCKER
SWITCH
CONTROL LOCATION DIAGRAM
4. EP SYSTEM: Flip both rocker switches to "O" position (off).
5. This appliance is equipped with an ignition device
which automatically lights the pilot. Do not try to light
the pilot by hand.
6. Remove front door.
7. Open manual pilot valve (CSD-1 Boilers Only).
8. Locate the gas control valve at the end of the gas
supply pipe going into the boiler. The gas control knob
is the knob located on top of the gas valve (see diagram
to right).
8. Rotate gas control knob clockwise
position to "OFF". Make sure knob rests against stop.
9. Wait five (5) minutes to clear out any gas. Then smell
for gas, including near the floor. If you smell gas,
STOP! Follow "B" in the safety information above on
this label. If you do not smell gas, go to the next step.
1. Set the thermostat to the lowest setting.
2. Turn off all electric power to the appliance if service is
to be performed.
3. Remove front door.
8
FOR YOUR SAFETY READ BEFORE OPERATING
If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury, or loss of life.
smell all around the appliance area
OPERATING INSTRUCTIONS
RESET SAFETY
SWITCH BUTTON
RM7890A
ELECTRONIC
CONTROL
PANEL
MAIN GAS ROCKER
SWITCH
from "ON"
TO TURN OFF GAS TO APPLIANCE
Figure 6: Operating Instructions, EP Ignition System
If you cannot reach your gas supplier, call the
fire department.
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it, call a qualified
service technician. Force or attempted repair may
result in a fire or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
ON
OFF
PILOT
GAS
INLET
GAS CONTROL KNOB
SHOWN IN "OFF" POSITION
11. EP SYSTEM
Turn gas control knob counterclockwise
"OFF" to "PILOT". When the proper position is reached
the gas control knob will pop up.
Turn on all electric power to the appliance.
Set the thermostat or operating control to desired
setting.
See control location diagram. On the electronic control
panel, flip the main power rocker switch to "l" position
(on). The "POWER" status indicator will light.
The pilot will light electronically. If pilot failure occurs,
the "ALARM" indicator will light. In case of pilot
failure, proceed to step 11.
Turn gas control knob counterclockwise
On the electronic control panel, flip the main gas valve
rocker switch to "l" position (on). The "MAIN" gas valve
indicator will light. Main burners will operate.
"MAIN" gas valve indicator will cycle on and off at the
same time as the thermostat or operating control and
the main burners.
Replace front door.
12. If the appliance will not operate, follow the instructions
"TO TURN OFF GAS TO APPLIANCE" and call your
service technician or gas supplier.
4. Rotate gas control knob clockwise
position to "OFF". Make sure knob rests against stop.
5. Close manual pilot valve (CSD-1 Boilers Only).
6. Replace front door.