RATING PLATE / LIGHTING INSTRUCTION LOCATION

ALLOW THE APPLIANCE TO COOL BEFORE PERFORMING ANY MAINTENANCE OR CLEANING.
Both the rating plate and lighting instructions are attached to a cable and inserted in the slot on the lower left
side of the appliance. It is recommended to remove the door prior to instruction removal. Using your fi ngers or
a tool such as a screw driver or pencil, gently pull both cables toward you. With the cable at the bulb end of the
slot, wiggle the rating plate out being careful not to tear the instructions as they pass through the slot.
To replace, slide the instructions and the chain back through the slot and re-attach the door (if removed).
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
C E R T I F I E D
CERTIFIED FOR / CERTIFIEE
POUR CANADA / USA
REFERENCE # 161746
NOT FOR USE WITH
WITH GLASS DOORS
CERTIFIED WITH THIS
WARNING:
TO THE APPLIANCE, WHICH WILL COME IN
CONTACT WITH TEH FLAMES, OTEHR THAN
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS:
TOP
FLOOR
RECESSED DEPTH
SIDES
BACK
MANTEL
SEE OWNER'S MANUAL
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate informa-
tion.
W415-1068 / A / 10.17.12
VENTED GAS FIREPLACE. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT
STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART
3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI/NFPA 501A. FOYER DE
CHAFFAGE AU GAZ AVEC ÉVACUATION. HOMOLOGUÉ POUR INSTALLATION DANS UNE CHAMBRE À COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIÉ POUR INSTALLATION DANS UNE MAISON
MOBILE SI SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SÉRIE DE MAISONS MOBILES ÉQUIPÉES AU GAZ EN VIGEUR AU CANADA OU AUX ÉTATS-UNIS DE LA NORME DE
SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREE, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ÉTATS-UNIS NE PEUT ETRE APPLIQUÉE, SE REFERER A LA NORME
RELATIVE AU CRITÈRE DE MESURES DE SÉCURITÉ CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURÉS, LES SITES ET LES COMMUNAUTÉS, ANSI/NFPA 501A. THIS
APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY; IF NONE, FOLLOW THE CURRENT ANSI Z223.1 OR CSA B149, INSTALLATION CODES. INSTALLER L'APPAREIL SELON LES
CODES D'INSTALLATION ANSI Z223.1 OU CSA-B149 EN VIGUER.
MODEL NATURAL GAS /
GAZ NATURAL
LHD62N
0-4500FT (0-1370M)
50,000 BTU/H
0"
0"
26"
0"
0"
12"*
SERIAL NUMBER/ NO. DE SÉRIE:
WARNING
!
MODEL PROPANE /
CLHD62N
CLHD62P
LHD62P
0-4500FT (0-1370M)
INPUT / ALIMENTATION
50,000 BTU/H
,000 BTU/H
MANIFOLD PRESSURE /
10" WATER COLUMN/D'UNE COLONNE D'EAU
PRESSION AU COLLECTEUR
11" WATER COLUMN/D'UNE COLONNE D'EAU
PRESSION D'ALIMENTATION MINIMALE
13" WATER COLUMN/D'UNE COLONNE D'EAU
PRESSION D'ALIMENTATION MAXIMAL E
LHD62
UN COMBUSTIBLE SOLIDE NE
N'AJOUTEZ PAS
COMBUSTIBLES :
DESSUS
0"
PLANCHER
0"
TABLETTE
12"*
W385-1864