Minimum Non-Combustible
Material Clearances
If Not Using Mantel
Note: If using a mantel, go to If Using
Mantel. If not using a mantel, follow the
information on this page.
You must have non-combustible material(s)
above the fireplace opening. Non-combus-
tible materials (such as slate, marble, tile,
etc.) must be at least 1/2 inch thick. With
sheet metal, you must have non-combus-
tible material behind it. Non-combustible
material must extend at least 8" up (for all
models). If non-combustible material is less
than 12", you must install the fireplace hood
accessory (24" and 30" models only). See
Figure 5 for minimum clearances.
IMPORTANT: If you cannot meet these
minimum clearances, you must operate
heater with chimney flue damper open.
If Using Mantel
You must have non-combustible material(s)
above the fireplace opening. Non-combus-
tible materials (such as slate, marble, tile,
etc.) must be at least 1/2 inch thick. With
sheet metal, you must have non-combus-
tible material behind it. Non-combustible
material must extend at least 8 inches up (for
all models). If non-combustible material is
less than 12", you must install the fireplace
hood accessory (24" and 30" models only).
Even if non-combustible material is more
than 12", you may need the hood accessory
to deflect heat away from your mantel shelf.
See Figure 5 and Figures 6 and 7 on page 9
for minimum clearances.
IMPORTANT: If you cannot meet these
minimum clearances, you must operate
heater with chimney flue damper open.
CGD3924NR, CGB3924NR and CGB3930NR
Non-Combustible
Material Distance (A)
12" or more
Between 8" and 12"
Less than 8"
Heat Resistant
Material
Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace
8
Requirements for
Safe Installation
Non-combustible material okay.
Install fireplace hood accessory (GA6050, GA6052,
or GA6053, see Accessories , page 21).
Non-combustible material must be extended to at
least 8". See Between 8" and 12" , above. If you
cannot extend material, you must operate heater
with flue damper open.
(A)
104306