24 CONNECTING THE FLUE TO THE BOILER

Note.
Before fitting the flue turret fill the condensate trap within the boiler by pouring a cupful of water into the flue outlet A.
Take care to ensure that the water is only poured into the flue outlet, and does not spill into the boiler casing.
1. Insert the flue assembly through the prepared hole in
the wall.
2. Locate the flue turret on the top of the boiler,
ensuring that the turret gasket is in place.
Check that the flue seal 'A' located
in the top of the flue manifold
is secure and giving an
effective seal.
3. Locate the flue into the
turret.
4. Secure the flue turret on
top of the boiler by
inserting the open ends of
the turret clamp under the
2 studs and fixing it in the
middle with the single M5 x
10mm pozi-hex screw
provided.
5. Flues over 1 metre long.
Fix the flue support bracket to
the wall, using the 4 wall plugs
and wood screws.
NB. The space bracket will utilise one
fixing hole only whilst used in conjunction
with the stand-off option.
25 WATER CONNECTIONS - CH
Notes.
1. For heating loads in excess of
60,000 Btu/h use 28mm x 22mm
connectors to connect the boiler
flow and return pipes to 28mm
system pipework.
2. Do not subject any of the isolating
valves to heat as the seals may be
damaged.
20
INSTALLATION
Isolating valve
(shown in the
open position)
Pressure gauge
22mm copper pipe
C.H. FLOW
Condensate drain pipe located here.
Drain
point
22mm copper pipe
C.H. RETURN
isar -
Installation and Servicing
Piping frame
Isolating valve
(shown in the
open position)