INSTALLING THE COOKTOP
13
ATTACHING A BLOWER
TRANSITION DUCT
Use a blower transition duct for all downward duct
installations to connect to 6" round standard ductwork. This
3
" x 10" rectangle to 6" round transition duct is available at
1 4
your local building supply store.
Install the transition duct to the blower outlet. Secure all
joints with duct tape to assure an airtight seal.
14
BLOWER ELECTRICAL CONNECTIONS
• Loosen the two screws and remove and discard the sheet
metal strap covering the 5-pin connector on the cooktop
bottom. Save the screws for reinstallation later.
22
Installation Instructions
Screw
(on other
side)
Screws
Remove
screws and
discard strap
• Connect the 5-pin plug on the blower assembly to the
matching 5-pin receptacle on the bottom of the cooktop.
• Fold all wires into the electrical enclosure. Secure the
enclosure with the screws removed earlier, making sure
that no wires are trapped.
15
CONNECTING THE DUCTWORK
Connect the ductwork prepared in Steps 6 and 7
to the blower.
5-pin
connectors
5-pin
connectors
Electrical
enclosure
Flexible
conduit