Napoleon BGD42NT Manual page 6

Napoleon bgd42nt; bgd42pt gas fireplace
Table of Contents

Advertisement

6
AIR TERMIN
AIR
AIR
AIR
AIR
TERMIN
TERMIN
TERMIN
TERMINAL INST
FIGURE 2
INSTALLATIONS
CANADIAN
A
12 INCHES
B
12 INCHES
C
12 INCHES*
D
18 INCHES**
E
12 INCHES**
F
0 INCHES
0 INCHES***
G
2 INCHES***
H
3 FEET
I
3 FEET
J
12 INCHES
K
6 FEET
L
7 FEET‡
M
12 INCHES††
N
16 INCHES
O
2 FEET†*
* * * * *
Recommended to prevent condensation on windows and thermal breakage
** ** ** ** **
Using a Napoleon soffit heat shield, W585-0096, or equivalent, the distance may be reduced to a minimum of 18". It is recommended to maximize the
distance to vinyl clad soffits.
***
***
***
***
***
The periscope GD-401 requires a minimum 18 inches clearance from an inside corner.
****
****
****
****
****
This is a recommended distance. For additional requirements check local codes.
† † † † †
Three feet above if within 10 feet horizontally.
‡ ‡ ‡ ‡ ‡
A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
††
†† ††
†† ††
Permitted only if the veranda, porch or deck is fully open on a minimum of two sides beneath the floor.
†* †* †* †* †*
Recommenced to prevent recirculation of exhaust products. For additional requirements check local codes.
W415-0221 / E / 04.09.02
AL INST
AL INSTALLA
AL INST
AL INST
ALLATIONS:
ALLA
ALLA
ALLA
U.S.A.
12 INCHES
Clearance above grade, veranda porch, deck or balcony.
9 INCHES
Clearance to windows or doors that open.
12 INCHES*
Clearance to permanently closed windows.
Vertical clearance to ventilated soffit located above the terminal within
18 INCHES**
a horizontal distance of 2 feet from the centerline of the terminal.
12 INCHES**
Clearance to unventilated soffit.
0 INCHES
Clearance to an outside corner wall.
Clearance to an inside non-combustible corner wall or protruding
0 INCHES***
non-combustible obstructions (chimney, etc.).
Clearance to an inside combustible corner wall or protruding com-
2 INCHES***
bustible obstructions ( vent chase, etc.).
Clearance to each side of the centerline extended above the meter
3 FEET****
/ regulator assembly to a maximum vertical distance of 15ft.
3 FEET****
Clearance to a service regulator vent outlet.
Clearance to a non-mechanical air supply inlet to the building or a
9 INCHES
combustion air inlet to any other appliance.
3 FEET†
Clearance to a mechanical air supply inlet.
Clearance above a paved sidewalk or paved driveway located on
7 FEET****
public property unless fitted with a heat shield kit GD-301.
12 INCHES****
Clearance under a veranda, porch, deck or balcony.
Clearance above the roof.
16 INCHES
Clearance from an adjacent wall including neighbouring buildings.
2 FEET†*
TIONS:
TIONS:
TIONS:
TIONS: