La Gard 8130 Installation Instructions

Hide thumbs Also See for 8130:

Advertisement

To ensure problem free installation and application, please read these instructions thoroughly before installing the 8130 Entry Device
and Lock.

8130 ENTRY DEVICE PARTS

• 8130 Entry Device w/Cable Assembly
• Metric Hardware Kit
2 Position Shunt (Jumper)
M4-0.7 5.5 mm Diam x 5.5 mm Shoulder Screws (2) (for Standard Mounting Method)
M4-0.7 x Phillips Head Screws (2) (for Alternate Mounting Method)
• English Hardware Kit
#8-32 .218 Diam x .2 Shoulder Screws (2) (for Standard Mounting Method)

LOCK OPTIONS

Dual-Handed Swing Bolt, Dead Bolt, Spring Bolt or Redundant Mechanical Lock
with one of the following lock codes:
ComboGard (33E V2.13)
ComboGard Pro (39E V1.01)
AuditGard (66E LGA V1.20)
TimeGard (TL11 V1.30 and V2.22)
Note: Hardware Kit included with lock.

OPTIONAL ACCESSORIES

• Knob Assembly - P/N 2666 (recommended for use with Dead bolt or Spring bolt locks).
• VisionGard Dial Assembly - P/N 2085 (for use with Redundant Mechanical lock). An entire range of LA GARD dials is available for
alternate dial options.
• Battery or Battery/Alarm Box (recommended if using with Time Delay/TimeLock. Alarm Box is required for use of certain features).
Small box: P/N 2788 or 2789
Large box: P/N 4001 or 4002
2666 Knob Assembly
(For use with Dead Bolt or Spring Bolt Locks)
The installation instructions are the basis for Security Agency Approvals. The lock installation must be done in accordance to these
instructions in order to maintain the labeled approval level.

DESIGN PARAMETERS FOR DEAD BOLT LOCKS

1. Bolt dimensions (nominal): .312 inches x 1.000 inches/8 x 25.4mm
2. Bolt movement (nominal): .465 inches/11.8mm
3. Bolt extension: .465 inches/11.8mm
4. Maximum load movable by the bolt: 5 lbs. (22N)
Note: LA GARD dead bolt locks may not open if more than 5 lbs. (22N) of force is applied to the end or side of the bolt.
5. Maximum load against bolt when thrown (all directions): 224.8 lbs. (1kN)
6. The lock can be fi tted to safes or vault doors of any material.
Note: As is the case with all mechanical and electronic locking devices, the container and boltworks must be designed to protect
the lock.
(P/N)738.098 Rev A • 04/09
INSTALLATION INSTRUCTIONS
Dual-Handed
Swing Bolt Lock
2085 VisionGard Assembly
(For use with Redundant
Mechanical Locks)
© copyright 2009
8130
Electronic Entry Device with Lock
Dead bolt Lock or
Spring Bolt Lock
2788 Small Battery Box
2789 Small Alarm/Battery Box
8130
Redundant
Mechanical Lock
4001 Large Battery Box
4002 Large Alarm/Battery Box
Kaba Mas LLC
page 1 of 5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8130 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for La Gard 8130

  • Page 1 4. Maximum load movable by the bolt: 5 lbs. (22N) Note: LA GARD dead bolt locks may not open if more than 5 lbs. (22N) of force is applied to the end or side of the bolt. 5. Maximum load against bolt when thrown (all directions): 224.8 lbs. (1kN) 6.
  • Page 2 4. Maximum load movable by the bolt: None Note: LA GARD swing bolt locks will not open if force is applied to the end or side of the bolt. 5. Maximum load against bolt when thrown (all directions): 1kN (224.8 lbs.) 6.
  • Page 3 ALTERNATE METHOD (TAMPER EVIDENT FOR VdS APPROVAL) The 8130 Entry Device comes with the mylar portion of the keypad unattached. (Figure 4) 1. Locate, drill and tap holes to mount the Entry Device to the outside of the safe door using the installation template provided.
  • Page 4 Use of the VISIONGARD Dial (P/N 2085) is recommended (Figure 9). An entire range of DOOR LA GARD dials is available for alternate dial options. 1. Locate, drill and tap holes to mount the Lock Assembly to the inside of the safe door using the installation template provided.
  • Page 5 10. Remove the mounting screw from the system card, and gently lift the system card out of the case. (Figure 12) 11. Insert the spindle through the spindle hole in the front of the door. Bolt 12. With the bolt retracted, carefully thread (clockwise) the Switch spindle into the drive cam of the lock assembly Card and...

Table of Contents