21. Image stabilization control
21.1.6
Combination and execution sequence of different sub-controls
Control name
IDC sensor
calibration control
See P.73
IDC sensor reflection
output
Developing bias Vpp
control
Developing bias duty con-
trol (control of the maxi-
mum amount of toner
sticking to the transfer belt)
Laser light intensity control
See P.14
Gamma characteristics
detection control
Registration correction
control
See P.14
106
Theory of operation Ver. 1.0 Nov. 2006
Simplified
image
stabilization
Check
Correction
Check
Check
Full adjustment
Fine adjustment
Full adjustment
Fine adjustment
Full adjustment
Full adjustment
Fine adjustment
Full adjustment
Complete
individual
image
registration
stabilization
➀
➀
➁
➁
➂
➂
➃
➃, ➅
➄
➄, ➆
➆
➇
➅
➈
control
➀
➁