York International ERHQ SERIES Installation Manual

R-22 outdoor split-system heat pump 13 seer - erhq series 2 to 3-1/2 tons

Advertisement

Quick Links

INSTALLATION MANUAL
R-22
OUTDOOR SPLIT-SYSTEM
HEAT PUMP
MODELS:
13 SEER - ERHQ SERIES
2 TO 3-1/2 TONS
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
UNIT INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Typical Installation with Required Clearances . . . . . . . . . . . . . . . . . . . 2
Minimum Suction Line Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Excess Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Insulation of Vapor Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Typical Quick Connect Refrigerant Line Set . . . . . . . . . . . . . . . . . . . . 4
Quick Connect Coupling Connections . . . . . . . . . . . . . . . . . . . . . . . . . 4
TEST Input Functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
X/L Output Categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

GENERAL

These outdoor heat pump units are designed to be connected to a
matching UPG indoor coil. They are equipped with a solid core filter-
drier located in the discharge line and a high pressure switch.
NOTE: These units are supplied with quick-connect coupling connec-
tions that are factory charged with refrigerant to be matched with the
appropriate pre-charged line set, and UPG indoor coil.
The outdoor unit is designed to be placed near the perimeter of the
home, typically alongside or at the back of the home, remote from the
indoor coil. The outdoor unit has been factory run-tested and all compo-
nents of the system are ready for easy, immediate installation.

SAFETY

This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury. It is also used to
alert against unsafe practices and hazards involving only property dam-
age
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE
SYSTEM IS LISTED

TABLE OF CONTENTS

ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
SYSTEM OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
INSTRUCTING THE OWNER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
LIST OF FIGURES
Outdoor Unit Control Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Low Voltage Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Demand Defrost Control Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Defrost Operation Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Heat Pump Flow Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
LIST OF TABLES
Defrost Initiate Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service, or mainte-
nance can cause injury or property damage. Refer to this manual
for assistance or for additional information, consult a qualified con-
tractor, installer, or service agency.
This product must be installed in strict compliance with the
enclosed installation instructions and any applicable local, state,
and national codes including, but not limited to building, electrical,
and mechanical codes.
INSPECTION
As soon as a unit is received, it should be inspected for possible dam-
age during transit. If damage is evident, the extent of the damage
should be noted on the carrier's delivery receipt. A separate request for
inspection by the carrier's agent should be made in writing. See Local
Distributor for more information.
LIMITATIONS
The unit should be installed in accordance with all National, State, and
Local Safety Codes and the limitations listed below:
1.
Limitations for the indoor unit, coil, and appropriate accessories
must also be observed.
R
P
Certified Quality
Management System
WITH ARI.
LISTED
ISO 9001
157650-UIM-B-1105

Advertisement

Table of Contents
loading

Summary of Contents for York International ERHQ SERIES

  • Page 1: Table Of Contents

    WHEN THE COMPLETE Management System SYSTEM IS LISTED WITH ARI. 13 SEER - ERHQ SERIES LISTED 2 TO 3-1/2 TONS TABLE OF CONTENTS GENERAL ..........1 ELECTRICAL CONNECTIONS .
  • Page 2: Unit Installation

    157650-UIM-B-1105 UNIT INSTALLATION The outdoor unit must not be installed with any duct work in the air stream. The outdoor fan is the propeller type and is not designed LOCATION to operate against any additional external static pressure. Before starting the installation, select and check the suitability of the The maximum and minimum conditions for operation must be location for both the indoor and outdoor unit.
  • Page 3: Minimum Suction Line Form

    157650-UIM-B-1105 OUTDOOR THERMOSTATS (All installations of this heat pump in Manufactured Homes built per HUD standards SHALL have an outdoor thermostat installed at the time of installation by the installer. In accordance with HUD std. 3280.714 (a) (1) (ii). Outdoor thermostat, Part number 3024- 6881/D shall be used and should be ordered at your nearest UPG Parts Source).
  • Page 4: Typical Quick Connect Refrigerant Line Set

    157650-UIM-B-1105 Install refrigerant lines to indoor coil first. (The couplings without Schrader Valves are to be connected to the indoor coil. See Figure BACK UP Form the tubing so it is properly aligned with the connections on the coil. Remove plugs and caps from connections. BACK UP Check that the rubber seals in connection ends are intact.
  • Page 5: Electrical Connections

    157650-UIM-B-1105 ELECTRICAL CONNECTIONS HEATER LIMIT SWITCH CONTACTOR GENERAL INFORMATION & GROUNDING (Not on all Units) Check the electrical supply to be sure that it meets the values specified DEFROST on the unit nameplate and wiring label. START RELAY CONTROL (Not on all Units) BOARD Power wiring, control (low voltage) wiring, disconnect switches and over current protection must be supplied by the installer.
  • Page 6: Test Input Functionality

    157650-UIM-B-1105 SYSTEM OPERATION TEST INPUT The control includes a TEST input connector that can be used for vari- ANTI-SHORT CYCLE DELAY ous testing functions during installation and service. The TEST input The control includes a five-minute anti-short cycle delay (ASCD) timer connector is shown in Figure 9.
  • Page 7: Defrost Initiate Curves

    157650-UIM-B-1105 Defrost Curves The control will initiate a defrost cycle every 6 hours (accumulated com- pressor run time) to recirculate refrigerant lubricants. This forced The control uses a set of defrost curve parameters that are selected defrost timer will be reset and restarted following the completion or ter- using the defrost curve selection jumper.
  • Page 8: Defrost Operation Curves

    157650-UIM-B-1105 REGION C Defrost Terminated TERMINATE CURVE REGION E REGION D No call for defrost Time Defrost (6 hour) prevented Defrost prevented from starting INHIBIT CURVE REGION B REGION A No call for Defrost Call for Defrost Time Defrost (6 hour) allowed AMBIENT TEMPERATURE FIGURE 10: Defrost Operation Curves COOLING OPERATION...
  • Page 9: Instructing The Owner

    157650-UIM-B-1105 CHARGE COMPENSATOR FIELD CONNECTED LINE INDOOR COIL (Empty in cooling / full in heating) (Not included in all Units) OUTDOOR COIL 4-WAY REVERSING VALVE FILTER DRYER (Solid core) COMPRESSOR SUCTION ACCUMULATOR BI-FLOW BI-FLOW LIQUID TXV/CHECK TXV/CHECK SENSOR VALVE OR ORIFICE (Heating) VALVE (Cooling) ** COOLING CYCLE FLOW FIELD CONNECTED LINE...
  • Page 10: Wiring Diagram

    157650-UIM-B-1105 WIRING DIAGRAM FIGURE 12: Wiring Diagram Unitary Products Group...
  • Page 11 157650-UIM-B-1105 NOTES Unitary Products Group...
  • Page 12 Subject to change without notice. Printed in U.S.A. 157650-UIM-B-1105 Copyright © by York International Corp. 2005. All rights reserved. Supersedes: 157650-UIM-A-0905 Unitary 5005 Norman Product York Group Drive 73069...