FACTORY DEFAULTS
User / Customer Code 1
Engineer Code
Circuit 1
Circuit 2
Circuit 3
Circuit 4
Circuit 5
Full set exit time
Night set exit time
Entry time
Bell ring time
These programming defaults are what the panel will revert to if a factory reset is
performed. The panel should come to you programmed in this way however if for
some reason you find it not to be the same, simply perform a factory reset and
this will revert the panel to the above settings.
SPECIFICATION FOR SOFTWARE REVISION NUMBER
The software revision number can be located on the top of the main processor
Power Supply
Mains Supply Voltage
PSU output voltage
Maximum output current
Aux current
Battery Fuse
Panel Quiescent
Maximum Cable Run 100 Metres
General
Operating temperature
Humidity
Dimensions
Control Panel Weight
Stand by Battery
C&K Securitech
1234
7890
Personal Attack (PA)
Alarm circuit
Alarm circuit isolated in home set
Alarm circuit with walkthrough
Entry / Exit circuit
30 seconds
15 seconds
30 seconds
15 minutes
230 v AC Nom
13.6 v DC Nom
1 amp (total)
500 mA Max.
1 A (20 mm)
40 mA
10 to 50 degrees centigrade
Up to 80% non condensing
304 mm (W)
220 mm (H)
89 mm (D)
1.45 kg Excluding Batt
2.6 Ah 12 v Rechargeable
6 Ah max.
2
V3.0