WARNING TONE . A 24 hour zone option which, following and alarm in
the day condition, allows the internal alarm sounder tone to be changed to
a rapid beeping. This will give a differential to other day time alarms.
EXAMPLE TO PROGRAM ZONE 1
ENTER 4-1. The TAMPER LED will show programmed as PA from factory
default.
To remove this option enter 0. The 0 key will remove all existing options so that
any or all LEDs that were showing will extinguish. The 0 key will only do this
after you have entered 4-1 and are in the programming options.
Now that the zone is totally cleared, select the primary option for this zone. The
secondary options are now available. If you want zone 1 to be programmed as
the final exit (FX) with the chime option, first select 4 -1 then clear the previous
selection by pressing the 0 key and illuminate LED 2 followed by LED 5.
Then press * to confirm. Accept tone will sound.Follow this procedure for all or
any zones you want to program.
NOTE...
All entry zones are isolated in home set.
Full set entry acts as normal alarm in night set.
Night set entry acts as normal alarm in full set.
If you require entry in both full and night set select both options on the same
zone.
OPTION 5. ENGINEER EVENT LOG REVIEW
The engineer log is organised into SET and UNSET events. The log will show
the first and subsequent alarms and isolated zones. First to alarm is shown by
the relevant LED being 'on'. Subsequent alarms are shown by the LED flashing
and isolated zones are shown by LED pulsing slowly. The buzzer will sound
whilst viewing the 'SET' logs and silent whilst viewing the 'UNSET' logs.
To view the engineer logs proceed as follows
From the program mode press the '5' key. The log routine will start with DAY 1
SET. The remaining logs are viewed by pressing the relevant key '2' for 2nd, '3'
for 3rd etc. on to log 9. Pressing the '0' key gives the last alarm condition for
both 'SET' and 'UNSET'.
The # key will alternate between 'SET' and 'UNSET' logs and can be used at
anytime. To exit logs press the * key.
C&K Securitech
11
Need help?
Do you have a question about the ACTIVE 5 and is the answer not in the manual?
Questions and answers