Connecting The Appliance To The Gas Supply - Dometic COE-C Operating And Installation Instructions

Cramer coe gas cooker
Table of Contents

Advertisement

The following applicable regulations must be observed when installing the gas appliance
EN 1645-1
EN 1646-1
EN 1648
EN 1949
EN 60335
EN 721
(In Germany, the 1988 Technical Rules Governing Liquid Gas,
and the rules specified in the DVGW worksheets G 607 (vehicles) and/or G 608 (boats)
must also be observed).

2. CONNECTING THE APPLIANCE TO THE GAS SUPPLY

Only gas-tight connection fittings may be used to connect the appliance to the gas supply
line.
The pipes for connecting the appliance should be made of galvanized iron or copper. These
pipes must be used with a gas-tight connection fitting. After the connection has been
established, the gas lines should be checked by applying a soap solution to the connecting
points; any leaks can be detected by the formation of bubbles.
IMPORTANT: DURING INSTALLATION AND CONNECTION OF THE
APPLIANCE, MAKE SURE THAT THE GAS INLET PIPE IS NOT TWISTED,
PULLED OR OTHERWISE STRAINED.
3. GAS CYLINDERS
Use gas cylinders that are commercially available in the country where the appliance was
purchased. The type of gas is indicated clearly on the package and on the indelible type
plate on the back of the appliance.
THE USE OF DIFFERENT GAS PRESSURES OR GAS TYPES FROM THOSE
SPECIFIED IN THE REGULATIONS CAN RESULT IN IRREGULAR
OPERATION OF THE APPLIANCE; THEREFORE, THE MANUFACTURER
SHALL ASSUME NO RESPONSIBILITY FOR IMPROPER USE OF THE
APPLIANCE.
Always comply with the following instructions:
The gas cylinder, including valves and pressure reducers (regulators), must be installed
vertically in the cabinet provided; the cylinders must be freely accessible.
It must be possible to replace the gas cylinder easily and without obstructions.
THE GAS CYLINDER VALVE SHOULD BE CLOSED WHEN NOT IN USE.
4