Daikin FTK09NMVJU Engineering Data page 13

Cooling only / heat pump - seer 18 models
Hide thumbs Also See for FTK09NMVJU:
Table of Contents

Advertisement

EDUS041502
FTK24NMVJU
THE MARK (→) SHOWS PIPING DIRECTION
39 (990mm)
REAR
LEFT
BOTTOM
FRONT GRILLE FIXING SCREWS
(INSIDE)
FLAPS
SIGNAL TRANSMITTER
1-7/8 (48mm)
13/16 (20mm)
WIRELESS REMOTE CONTROLLER
(ARC480A9)
4.1.2
Heat Pump
FTX09/12NMVJU
THE MARK (→) SHOWS PIPING DIRECTION
30-5/16 ( 770 mm )
REAR
LEFT
FRONT PANEL FIXING SCREWS
BOTTOM
FLAPS
SIGNAL TRANSMITTER
1-7/8 ( 48 mm )
13/16 ( 20 mm )
WIRELESS REMOTE CONTROLLER
( ARC480A8 )
Split Type Air Conditioners FTK(X)-N Series
RIGHT
(
INCLUDING
MOUNTING PLATE
10-7/16 (265mm)
10-3/8 (263mm)
UP AND DOWN WIND DIRECTION
CONTROL BLADE MOVABLE RANGE
SIGNAL RECEIVER
OPERATION LAMP
TIMER LAMP
INDOOR UNIT ON/OFF SWITCH
ROOM TEMP. THERMISTOR
(INSIDE)
MODEL NAME PLATE
BLADE ANGLES
UP/DOWN (AUTOMATIC)
COOLING, DRY
10˚
15˚
30˚
70˚
55˚
RIGHT/LEFT (MANUAL)
INCLUDING
MOUNTING PLATE
8-7/8 ( 225 mm )
8-3/4 ( 223 mm )
RIGHT
( INSIDE )
UP AND DOWN WIND DIRECTION
CONTROL BLADE MOVABLE RANGE
SIGNAL RECEIVER
OPERATION LAMP
TIMER LAMP
INDOOR UNIT ON/OFF SWITCH
ROOM TEMP. THERMISTOR
( INSIDE )
MODEL NAME
PLATE
BLADE ANGLE
UP/DOWN ( AUTOMATIC )
RIGHT/LEFT
( MANUAL )
COOLING
DRY
50˚
50˚
HEATING
FAN
15˚
65˚
65˚
)
1-15/16 (50mm) MIN
(SPACE FOR
GENERAL RATING
MAINTENANCE)
NAME PLATE
TERMINAL BLOCK
WITH EARTH
TERMINAL
(INSIDE)
ABOUT 15-3/4 (400mm)
GAS PIPE φ5/8 (φ15.9mm) CuT
ABOUT 17-5/16 (440mm)
ABOUT 18-1/8 (460mm)
DRAIN HOSE
LIQUID PIPE φ1/4 (φ6.4mm) CuT
(CONNECTING PART
I.D. φ9/16 (φ14mm)
O.D. φ5/8 (φ16mm)
FAN
25˚
80˚
65˚
WALL HOLE FOR EMBEDDED PIPING
1-7/8 (48mm)
φ3-1/8 (φ80mm) HOLE
STANDARD LOCATIONS OF WALL HOLES
REQUIRED SPACE
GENERAL RATING
NAME PLATE
TERMINAL BLOCK
1-15/16 ( 50 mm ) MIN
WITH EARTH
( SPACE FOR
TERMINAL
MAINTENANCE )
( INSIDE )
5-3/16 ( 132 mm )
GAS PIPE φ 3/8 (φ 9.5 mm ) CuT
( THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 14-3/16 ( 360 mm ))
LIQUID PIPE φ 1/4 (φ 6.4 mm ) CuT
( THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 16-1/8 ( 410 mm ))
STANDARD LOCATIONS OF WALL HOLES
1-7/8 ( 48 mm )
WALL HOLE FOR EMBEDDED PIPING
φ 2-9/16 (φ 65 mm ) HOLE
AIR FLOW (INDOOR)
1-15/16 (50mm) MIN
REQUIRED SPACE
(SPACE FOR
MAINTENANCE)
DRAIN HOSE
GAS PIPE
ABOUT 14-3/16 (360mm)
ABOUT 14-3/8 (365mm)
ABOUT 17-3/4 (450mm)
39 (990mm)
29-3/8 (746mm)
5 (126.5mm)
2-3/8 (60mm)
WALL HOLE
φ3-1/8 (φ80mm) HOLE
AIR FLOW ( INDOOR )
1-15/16 ( 50 mm ) MIN
( SPACE FOR
MAINTENANCE )
DRAIN HOSE
LIQUID PIPE
ABOUT 13 ( 330 mm )
DRAIN HOSE
ABOUT 14-9/16 ( 370 mm )
( CONNECTING PART
ABOUT 15-3/8 ( 390 mm )
I.D. φ 9/16 (φ 14 mm )
O.D. φ 5/8 (φ 16 mm )
( THE HOSE LENGTH OF OUTSIDE
THE UNIT IS ABOUT 18-1/2 ( 470 mm ))
30-5/16 ( 770 mm )
21-1/8 ( 536.6 mm )
4-9/16 ( 116.5 mm )
1-7/8 ( 48 mm )
WALL HOLE
φ 2-9/16 (φ 65 mm ) HOLE
Dimensions
LIQUID PIPE
3D091782
GAS PIPE
3D091702
11