SPECIFICATIONS

ELECTRICAL DATA
TYPE
INDOOR UNIT
OUTDOOR UNIT
COOLING CAPACITY
HEATING CAPACITY
POWER SOURCE
RUNNING CURRENT
INPUT WATTS
E.E.R.
STARTING CURRENT
MOISTURE REMOVAL
AIRCIRCULATION INDOOR
AIRCIRCULATION OUTDOOR
MAXIMUM CURRENT
FAN SPEED
Discrimination
High speed
Med speed
INDOOR UNIT
Low speed
Quiet
Discrimination
OUTDOOR
UNIT
Speed
NOISE LEVEL
High speed
Med speed
INDOOR UNIT
Low speed
Quiet
Cooling
OUTDOOR
UNIT
Heating
Note : Static pressure : 47Pa
Duct length : Inlet 1m, Outlet 2m
DIMENSIONS
INDOOR UNIT
OUTDOOR UNIT
WEIGHT
Gross / Net
INDOOR UNIT
OUTDOOR UNIT
Gross / Net
2008.01.21
Cooling & Heating
ARYA30LBTU ARYA36LBTU
AOYA30LBTL AOYA36LBTL
8.5 kW
10.0 kW
230 V 50 Hz
11.6 A
Cooling
Heating
11.7 A
Cooling
2.65 kW
Heating
2.68 kW
Cooling
3.21 kW/kW
Heating
3.73 kW/kW
15 A
2.5 L/hr
2,100 m3/hr
3,600 m3/hr
17.0 A
MFG-45RVN
1,270 r.p.m.
980 r.p.m.
790 r.p.m.
630 r.p.m.
MFE-36TV
850 r.p.m.
42 dB
37 dB
32 dB
29 dB
53 dB
55 dB
H x W x D
270 x 1,135 x 700 mm
H x W x D
830 x 900 x 330 mm
47 kg / 40 kg
70 kg / 62 kg
COMPRESSOR AND REFRIGERANT
COMPRESSOR TYPE
DISCRIMINATION
9.4 kW
WEIGHT (with oil)
11.2 kW
STANDARD REFRIGERANT
230 V 50 Hz
REFRIGERANT TYPE
12.8 A
MAX PIPE LENGTH
13.6 A
MAX PIPE HEIGHT
2.93 kW
3.10 kW
FULL CHARGE
3.21 kW/kW
3.61 kW/kW
15 A
ADDITIONAL CHARGE
3.0 L/hr
2,100 m3/hr
4,000 m3/hr
20.0 A
MFG-45RVN
1,270 r.p.m.
980 r.p.m.
790 r.p.m.
630 r.p.m.
MFE-36TV
950 r.p.m.
42 dB
37 dB
32 dB
29 dB
54 dB
55 dB
1
Hermetic type, Inverter,
4 poles, 3 phase,
DC motor, Twin Rotary
5KD240XAD21
Pipe length 20 m
30 m
40 m
50 m
16.3 kg
2,100 g
R410A
50 m
30 m
2,100 g
2,500 g
2,900 g
3,300 g
40 g/m