IMPORTANT WARNING!

This stove must not be installed into a chimney that serves any other heating
appliance. There must not be an extractor fan fitted in the same room as the stove as
this can cause the stove to emit fumes into the room.
The complete installation must be done in accordance with current Irish/UK/European
Standards, Regulations and Local Codes. It should be noted that the requirements and
these publications may be superseded during the life of this manual.
PRE-INSTALLATION ASSEMBLY
1. After removing the stove from its pack, fit the glass door (3) onto the stove using the hinge
bar which is mounted on the glass door (3).
2. Remove the stove from the pallet and position it in the final installation position.

FLUES

Flues should be vertical wherever possible and if a bend is necessary, the angle should not be
more than 37.5° with the vertical. Horizontal flue runs should be avoided except in the case of a
back outlet connection where the length of the horizontal section should not exceed 150mm or
6 inches.

CHIMNEY

The EIRECO Wood Burning Stove is a radiant room heater and must be connected to a chimney
2
of the proper size and type. The chimney must have a cross-sectional area of at least 124 cm
or
2
20 inches
or a diameter of at least 150mm or 6 inches. Never connect to a smaller size
chimney! Do not connect to a chimney serving another appliance. Minimum chimney height 4.6
m or 15 feet from floor on which stove is installed. A flue that has proved to be unsatisfactory,
particularly with regard to down draught should not be used for venting this appliance until it
has been examined and any faults corrected. An existing masonry chimney should be inspected
and if necessary repaired by a competent mason or relined using an approved lining system.
The stove must be connected to a chimney with a minimum continuous draught of 0.05 w.g.
(12 Pa). Poor draught conditions will result in poor performance.