INSTALLATION CHECK LIST
Flue System
Minimum Flue or Chimney Height of 4.1 m or 15'
Appliance should be connected to a minimum of 150 mm or 6 inches flue pipe with a horizontal run not
exceeding 500mm or 20 inches.
Appliance should be connected to a chimney of less than 250 mm or 8 inches in diameter (otherwise the
chimney must be lined with a 150 mm or 6 inch flue liner).
The chimney venting position must be above the main ridge of the roof or adjacent outside obstructions.
The chimney serving this appliance should not serve any other appliance.
Access should be provided to the chimney serving the appliance to allow for cleaning.
Location
Clearance to combustible materials must be adhered to as described in the Clearance to Combustible section.
The stove must be installed on a floor protector that covers the area under the stove and extends 457.5 mm or
18 inches to the front and 203.5 mm or 8 inches to the sides and back.
Ventilation & Combustion Air Requirements
The room in which the appliance is located should have an air vent of adequate size to support correct
combustion (see Ventilation & Combustion Air Requirement Section for specific details).
Warning: Use only replacement parts recommended by EIRECO. Making
unauthorised modifications or using unauthorised parts will invalidate your
guarantee and may cause damage or injury.
20
EIRECO Wood Burning Stove Installation and Operating Instructions