Kenwood TK-2207 Service Manual page 36

Hide thumbs Also See for TK-2207:
Table of Contents

Advertisement

TK-2207
Common Section
Item
Condition
1.Setting
1) BATT terminal votage:7.5V
2) SSG standard modulation
[Wide] MOD:1kHz,DEV:3kHz
[Narrow] MOD:1kHz,DEV:1.5kHz
2.VCO lock
1) CH:High
voltage
RX
2) CH:Low
3.VCO lock
3) CH:High
voltage
PTT:ON
TX
4) CH:Low
PTT:ON
Transmitter Section
Item
Condition
1.Frequency
1) CH:High
Adjust
2) PTT:ON
2.High power TEST CH: Low
Adjust
BATT terminal voltage:7.5V
PTT:ON
3.Low power TEST CH: Low
Adjust
BATT terminal voltage:7.5V
PTT:ON
4.Max deviation TEST CH: Center
Adjust
[Wide]
AG:1kHz/150mV
Deviation meter filter
LPF:15kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
5.VOX 1
TEST CH:Center
Writing
AG:1KHz/45mV
36
ADJUSTMENT /
Test equipment
Power meter
DVM
Test equipment
Frequency counter ANT
Power meter
Low'
Ammeter
Center
High'
High
(5 points)
Low'
Center
High'
High
(5 points)
Power meter
Low
Deviation meter
High
Oscilloscope
(3 points)
AG
AF VTVM
调整
Measurement
Terminal
ANT
TC2
CV
TC1
Measurement
Terminal
VR1
Programming
Software:KPG-87D
ANT
SP/MIC connector
Adjustment
Parts
Method
4.0V
Check
4.2V
Check
Adjustment
Parts
Method
173.900MHz
4.2kHz
(According to
the lager +,–)
2.2kHz
(According to
the lager +,–)
Specifications/
Remark
±0.1V
0.6V or more
±0.1V
0.6V or more
Specifications/
Remark
±50Hz
5.0W ±0.1W
1.9 A or less
1.0W ±0.1W
0.9 A or less
±50Hz
±50Hz