Kenwood TK-2207 Service Manual page 34

Hide thumbs Also See for TK-2207:
Table of Contents

Advertisement

TK-2207
Adjustment points TX-RX unit (X57-687)
Component side view
VR1 : Frequency adjustment
BPF : Band-pass wave form test point
CV : Lock voltage adjustment terminal
Foil Side View
TC1 : Transmit lock voltage adjustment
TC2 : Receive lock voltage adjustment
CV : Lock voltage adjustment terminal
34
ADJUSTMENT /
RSSI
BATT+
PCTV
5R
5C
5M
5T
VR1
CV
MICI
MICO
S401
S403
PTT
SW1
J301
EXT. SP/EXT. MIC
Fig. 1 Adjustment points / 图 1 调整点
调整
TX-RX 单元(X57-687) 调整点
元件面视图
BPF
CN13
ANT
B
SB
TX-RX UNIT
Component side view
SP–
SP+
VR1 : 频率调整
BPF : 带通波形测试点
CV : 锁定电压调整终端
箔面视图
S402
SW2
TX-RX UNIT
Foil side view
TC1
TC2
CV
MICI
RXAFO
RXAFI
MICO
TC1 : 发射锁定电压调整
TC2 : 接收锁定电压调整
CV : 锁定电压调整终端