1
2. Channel Status LEDs
Provide an at-a-glance view of the status of each channel as
indicated in the table below:
Color
Status
Constant Blue
Normal Operation
Constant Bright Blue
Indicates the audio signal is clipping. Reduce volume level to help
eliminate potentially damaging audio signals from reaching the speakers.
The temperature of the individual amplifier heatsink is above 95˚C. If this
Flashing Blue
occurs, the channel will not pass audio. The channel status LED will return
to constant blue when the temperature of the amplifier card returns to
normal. Then the channel will automatically resume passing audio.
The temperature of the chassis is above 58˚C, and the amplifier will no
All Channels Flashing
longer pass audio. After the chassis temperature returns to normal, all the
Blue
channel status LEDs will return to constant blue and the amplifier will
resume normal operation.
Basic Operation
2
Note:
When the main power transformer temperature
exceeds 100˚C:
• the transformer will deactivate
•the channel status LEDs will no longer be lit
•the red standby LED will flash rapidly