Electronic Timer
Info
Installation Instructions
Electronic Timer
Woche
Tag
Prog
ON
OFF
Manuell
Auto
Zufall
Astro
AUS
EIN
Man/Auto
Einstellen
Enter
Programmed Switch Times will not be activated during manual operation.
Manual operation is superior to automatic types of operation.
Power failure clears the display. In case of power failure of up to 2 hours all programmed data remain.
Should failure last longer than 2 hours, controller switch to manual operation after return of power,
display flashes until pushing any optionalkey. Following a re-setting of the actual time, calendar week
and weehday is essential (see chap. 3.1 - 3.5).
Should the Timer not react on pushing keys (due to false operation), pull off the plugged-on
controller unit for at least 20 minutes. By doing so a reset for the internal microprocessor is garanteed.
Programmed data remain uneffected.
Attention, warning of danger:
The electronic timer was developed for automatic switching of lighting fixtures. In case that they are
used for other purposes which might cause risks (e.g. switching of heaters), the user should prevent
such risks by applying additional appropriate safetly measures.
Electronic Timer
1.
Description of Functions
Mo
The Electronic Timer supported by a Microprocessor is placed into
Di
Mi
a 58 mm recessed box and free of maintenance.
Do
Fr
A reted load of max. 1000 VA can be controlled. The Timer is
Sa
So
equipped with 9 memory registers free programmable for one
Switch-on respectively one Switch-off Time each. These times can
be coordinated to any combination of weekdays.
The Timer is equipped with 4 types of operation:
1.) Manual Mode (see chap. 4.1)
Connected loads can be switched by means of keys.
2.) Automatic Mode (see chap. 4.2)
Programmed Switch Times are being realized.
3.) Operation with Random Generator (see chap. 4.3)
Programmed Switch Times will be varied up to ± 15 min. to
simulate presence of persons.
4.) Operation with Astro Mode (see chap. 4.4)
Programmed Switch Times will be adjusted to times of sunrise and
sunset.
Combinations of various modes are possibles.
2.
Installation and Starting
2.1 Wiring Diagram
Caution: The installation and assembly of electrical equipment
may be carried out only by a skilled person.
Neutral conductor required!
12/96
Order No.: 0385 ..
Page 1 of 8

Advertisement

loading

Summary of Contents for Gira 0385

  • Page 1 GIRA Electronic Timer Info Installation Instructions Electronic Timer Order No.: 0385 .. Description of Functions Woche Prog The Electronic Timer supported by a Microprocessor is placed into a 58 mm recessed box and free of maintenance. A reted load of max. 1000 VA can be controlled. The Timer is...
  • Page 2 GIRA Electronic Timer Info Installation Instructions Programming Adjustment of Calendarweek Time of Switch Time Summer-/Wintertime Display Woche Prog Display Wintertime Switch Time No. Display Summertime Manuell Auto Zufall Astro Manual mode Automatic Astro Time Random mode on mode on mode on...
  • Page 3 GIRA Electronic Timer Info Installation Instructions 3.2 Setting of Summertime/Wintertime Woche Prog Symbol is marked (dot under ), adjusted symbol flashes. Set Summertime/Wintertime via key EIN or AUS. Confirm with Enter. Manuell Auto Zufall Astro Man/Auto Einstellen Enter 3.3 Calendarweek...
  • Page 4 GIRA Electronic Timer Info Installation Instructions Programming of Switch Times Woche Prog 3.6.1 Setting of Switch Time Number Dot is forward to „Prog“, symbol for Switch-on Time 1 flashes. For further Switch Time Numbers please touch keys EIN or AUS.
  • Page 5 GIRA Electronic Timer Info Installation Instructions Alterations of setting realize with key AUS. Flashing mark is Woche Prog forward to Mo (Monday). Enter programms day, AUS leaves a day out. A programmed day is indicated permanently, the flashing mark moves a day further. In case So (Sunday) is programmed or left out, the next Switch Time can be programmed (see chap.
  • Page 6 GIRA Electronic Timer Info Installation Instructions 4.3 Random Generator Programmed Switch Times will vary up to ± 15 minutes when Random Generator is being switched to Automatic Mode. All Switch Times of a day will be changed to the same random time to avoid overlapping of switching operations.
  • Page 7 GIRA Electronic Timer Info Installation Instructions If it is required to switch on lighting at 03.00 hours in the morning and off at sunrise (SA), use following programming: Activate Astro Mode, Switch Time 1: Mon-Sun 03.00 h ON; 10.00 h OFF.
  • Page 8: Acceptance Of Guarantee

    Gira Giersiepen GmbH & Co. KG Postfach 1220 D-42461 Radevormwald Telefon: +49 / 21 95 / 602 - 0 Telefax: +49 / 21 95 / 602 - 339 Internet: www.gira.de Electronic Timer 12/96 Page 8 of 8...