Specifications - Lennox L30 BF-2 Installation And Operation Manual

Freestanding vented gas fireplace heater
Table of Contents

Advertisement

SPECIFICATIONS: Model L30 BF-2
Approx. Sq. Ft.
Heating Capacity 1500 sq. ft.
Flue Size
4" - Top Vent
Height Overall
29"
Height to Flue
Outlet
30 3/8"
Width
29 7/8"
Depth
16 1/8"
Fuel
Natural Gas (standard)
(or) LP Gas (convertible).
Gas inlet 3/8" NPT-Male / Flex Line
(or) remove flex, 3/8" NPT–Female Flare.
Performance
Variable Flame Control.
Features
High Efficiency Heat Exchanger.
Natural Convection & Radiant Heat.
Standing Pilot / Operates During Power
Outages. Remote Control & Wall
Thermostat Capable.
Technical
Honeywell Combination Gas Control
Features
Valve, Millivolt - VS8520E. Safety Shut
Down Sensor (Spill Switch).
Pan Burner with Tuned Ports.
Radiant & Fan Assisted Convection
Heat.
Safety Test
Tested and certified by CSA to ANSI
standards. Z21.88 – (1998) CSA 2.33 -
(1998). Vented Gas Fireplace Heater .
Heat Input
25,000 to 37,000 BTU's (Nat. Gas)
28,000 to 35,000 BTU's (Propane)
Ship Weight
200 lb.'s
Dimensions shown are approximations only (+ / - ¼")
GAS TYPE
Orifice Size
Minimum Supply Pressure
Maximum Supply Pressure
HIGH SETTING
Manifold Pressure
Input BTU / HR
LOW SETTING
Mainfold Pressure
Input BTU / HR
Altitude - U.S.A. 0-4,500 Ft. (0-1372M) No derating
Altitude - Canada 0-4,500 Ft. (0-1372M) No derating
For installation higher than altitudes shown above, reorifice per Gas
Codes.
This Appliance is equipped at the factory for the use with Natural Gas or Propane (LP). Appliances using propane must
be field conversed using the LP Conversion Kit supplied with appliance.

SPECIFICATIONS

NATURAL
PROPANE
GAS
(LP)
#31 -.120
#50-.070"
4.5" WC
10.5" WC
10.5" WC
13.0" WC
3.5" WC
10.0" WC
37,000
35,000
1.8" WC
6.6" WC
25,000
28,000
PAGE 22
Top View
Side View
~ Square feet heating capacities are approximations only.
They will vary depending upon level of insulation, climate,
house design, ceiling height, ambient outside tempera-
tures and how stove is operated.
CLEARANCES TO COMBUSTIBLES
Back Wall Min.
Side Wall Min.
Corner (45 angle)s
stove corner to wall, min.
Ceiling Height Minimum
Alcove Min. Height
Alcove Min. width
Alcove - Max. Depth into
stove face to alcove opening
* With the orifice, manifold pressure and input
ratings shown above.
2 In. / 51 mm
12 In. / 305 mm
4 In. / 102 mm
65 In. / 1651 mm
65 In. / 1651 mm
54 In. / 1372 mm
24 In. / 610 mm

Hide quick links: