Panasonic CS-A7CKP Service Manual page 28

Hide thumbs Also See for CS-A7CKP:
Table of Contents

Advertisement

CS-A7CKP CU-A7CKP5 / CS-A9CKP CU-A9CKP5 / CS-A12CKP CU-A12CKP5
Quiet Operation Control
(For Heating Mode)
• Purpose of this operation is to provide quite heating operation compare to normal operation.
• When the Quiet Mode is set at the remote control, Quiet Mode LED illuminates, the sound level will be automatically
decreased 2 dB (Lo), decreased 3 dB (Hi, Me), against the present sound level operation.
• Quiet setting of fan speed rpm refer to Indoor Fan Speed Control.
• Manual Airflow Direction:-
− Rpm control during Lo, Me & Hi Cool
• Auto Airflow Direction:-
− Rpm control depends on the piping air temperature sensor of Indoor heat exchanger
• Quiet Mode Operation will stop if:-
− Quiet mode button is pressed again.
− Stopped by ON/OFF switch.
− Timer OFF activates.
− Powerful mode button is pressed.
28