Panasonic CS-A7CKP Service Manual page 20

Hide thumbs Also See for CS-A7CKP:
Table of Contents

Advertisement

CS-A7CKP CU-A7CKP5 / CS-A9CKP CU-A9CKP5 / CS-A12CKP CU-A12CKP5
Quiet Operation Control
(For Cooling Mode or cooling region of Soft Dry Mode)
• Purpose of this operation is to provide quite cooling operation compare to normal operation.
• When the Quiet Mode is set at the remote control, Quiet Mode LED illuminates, the sound level will be automatically decreased
2 dB (Lo), decreased 3 dB (Hi, Me), against the present sound level operation.
• Quiet setting of fan speed rpm refer to Indoor Fan Speed Control.
• Dew formation become severe at Quiet Lo cool, therefore Quiet Lo cool is operated only 1h 30 min (1h QLo, 30 min QLo + 50).
After that, it goes back to Lo cool (However Quiet LED remains on).
• Manual Airflow Direction:-
− RPM control during Lo cool
− RPM control during Hi & Me cool
• Auto Airflow Direction:-
• Quiet Mode Operation will stop if:-
− Quiet mode button is pressed again.
− Stopped by ON/OFF switch.
− Timer OFF activates.
− Powerful mode button is pressed.
− When change mode to Air Circulation mode.
20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-a9ckpCu-a9ckp5Cs-a12ckpCu-a12ckp5Cu-a7ckp5

Table of Contents