9.2

"T" Models

PC TOO COLD
PC TOO WARM
FC TOO COLD
FC TOO WARM
TOTAL CABINET TOO WARM
FC COOLING - PC WARMING
* FC fan not going (alarm will
sound and fault code will be
displayed)
* Short of gas
* PC sensor inaccurate
* Evaporator iced up
* No refrigeration
* Fans not working (alarm will
sound and fault code will be
displayed)
* Power/control module
failure
* PC delivery duct blocked
* FC sensor location
* Faulty sensor
* PC faulty fanr
* No refrigeration
* No refrigeration
* Iced up evaporator
-
Check power to plug
-
Check polarity
-
Replace fan
-
Check run percentage, if high check evaporator
-
Check fully flooded evaporator, check for leak
-
Check calibration of sensor ice point using interface binary
or refer to thermistor resistance table in service manual
-
Check defrost element, check continuity
-
Check door seal/door left open
-
Does cabinet run? If no, check power supplies. If yes,
check refrigeration system
-
If running, check for live frost/fully flooded evaporator. If
not, check for leak
-
Is there a 12Volt supply, PC light working
-
If yes, check fan connection(s) at fan end, also at
power/control module end of the harness
-
If no, check for power/control module failure
-
Are lamp / interface L.E.D.'s working
-
If not check display module connection
-
If OK is compressor running ?
-
If not replace power/control module
-
De-ice area behind chassis
-
-
Check set temperature
-
Sensor clipped and located in correct position
-
Check calibration of sensor ice point using interface binary
or refer to thermistor resistance table in service manual
-
Check PC cooling, fan running
-
Does cabinet run? If no check power supplies. If yes
check refrigeration system
-
If running, check for live frost/fully flooded evaporator. If
not, check for leak
-
Does cabinet run? If no check power supplies. If yes
check refrigeration system
-
If running, check for live frost/fully flooded evaporator
-
If not, check for leak
-
Compressor is not running, check power/control module
voltage outputs
-
Check compressor and ancillaries
-
Check defrost circuit continuity
-
Doors sealing, adjust
-
Is PC fan is running? (alarm will sound and fault code will
be displayed if faulty). If not, refer PC too warm
46