NOISY FAN FC
ICE BUILD UP IN
COMPARTMENT
REFRIGERATION NOISE
* Ice on cover
* Ice on grill
* Fan off mountings
* Wires touching
* Capillary touching
* Fan motor noisy
* Wires pulled tight
* Doors sealing
* Popping, farting
* Gurgling, whistling
-
Clear ice off cover and check doors are sealing
-
Clear ice off grill and check doors are sealing
-
Refit
-
Tuck wires away from fan blade
-
Shift capillary from fan area, make sure it is not touching
any part of the cabinet
-
Fit replacement
-
Re route wiring
-
Check gaskets are sealing, adjust gaskets
-
Check fans are operating
-
Evacuate and recharge with ISCEON 49
-
Check alignment of capillary and apply sound dampening
tape