Configuring The Advanced Sata Or Sas Hardware Raid - Lenovo THINKSERVER 387 Hardware Maintenance Manual

Lenovo server user manual
Table of Contents

Advertisement

virtual drive data might be corrupted. Be sure to back up the data before running a consistency check if you
suspect the data might be corrupted.
To run a consistency check using the LSI Software RAID Configuration Utility program, do the following:
1. Start the LSI Software RAID Configuration Utility program. See "Starting the LSI Software RAID
Configuration Utility program" on page 74.
2. On the main interface of the program, select Check Consistency and follow the instructions on the
screen.
The consistency check rate is the rate at which consistency check operations are run on a system. The
consistency check rate can be configured between 0 percent and 100 percent. At 0 percent, the consistency
check is done only if the system is not doing anything else. At 100 percent, the consistency check has a
higher priority than any other system activity.
To configure the consistency check rate using the LSI Software RAID Configuration Utility program, do
the following:
Note: Using a consistency check rate of 0 or 100 percent is not recommended. The default value is 30
percent.
1. Start the LSI Software RAID Configuration Utility program. See "Starting the LSI Software RAID
Configuration Utility program" on page 74.
2. On the main interface of the program, select Objects ➙ Adapter ➙ Chk Const Rate.
Note: Use up and down arrow keys to navigate between items and press Enter to select an option.
3. Set the consistency check rate by typing a desired value from the keyboard directly.
Installing and using the MegaRAID Storage Manager program
You can install and use the MegaRAID Storage Manager program to manage the RAID array and RAID
controller in an operating system environment after configuring RAID.
The installation package for the MegaRAID Storage Manager program is on the ThinkServer EasyStartup
DVD. After you enter the operating system, insert the ThinkServer EasyStartup DVD into the optical drive.
The installation package for the MegaRAID Storage Manager program is located in the Utilities and Others
folder in the root directory of the DVD.
To install and use the MegaRAID Storage Manager program, refer to the following chapters in the MegaRAID
SAS Software User Guide on the documentation DVD that comes with your server:
Note: Some information in these chapters might be intended for the advanced SATA/SAS hardware RAID
configurations and might not apply to the onboard SATA software configurations.
• "MegaRAID Storage Manager Overview and Installation"
• "MegaRAID Storage Manager Window and Menus"
• "Monitoring System Events and Storage Devices"
• "Maintaining and Managing Storage Configurations"
The MegaRAID SAS Software User Guide is also available on the Lenovo Web site at:
http://www.lenovo.com/ThinkServerUserGuides

Configuring the advanced SATA or SAS hardware RAID

Some server models come with a required RAID card to provide advanced SATA/SAS hardware RAID
functions to the server. You can also purchase the RAID card from Lenovo and install it into server models
.
Chapter 5
Configuring the server
79

Advertisement