Lenovo ThinkCentre 7244 Hardware Maintenance Manual page 61

Lenovo desktop computer hardware maintenance manual
Hide thumbs Also See for ThinkCentre 7244:
Table of Contents

Advertisement

Diagnostic Error Code
005-197-XXX Video test warning
005-198-XXX Video test aborted
005-199-XXX Video test failed, cause unknown
005-2XX-XXX 005-3XX-XXX Video subsystem error
006-000-XXX Diskette interface Test Passed
006-0XX-XXX Diskette interface error
006-195-XXX Diskette interface Test aborted by user
006-196-XXX Diskette interface test halt, error threshold
exceeded
006-197-XXX Diskette interface test warning
006-198-XXX Diskette interface test aborted
006-199-XXX Diskette interface test failed, cause
unknown
006-25X-XXX Diskette interface Error
011-000-XXX Serial port Interface Test Passed
FRU/Action
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 43
2. Re-run test
3. Replace the component called out in warning
statement
4. Replace the component under test
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 43
2. Flash the system and re-test. See "Updating
(flashing) BIOS from a disc" on page 560
3. Go to "Undetermined problems" on page 69
1. Go to "Undetermined problems" on page 69
2. Flash the system and re-test. See "Updating
(flashing) BIOS from a disc" on page 560
3. Replace component under function test
1. Video card, if installed
2. System board
No action
1. Diskette drive Cable
2. Diskette drive
3. System board
Information only Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. If a component is called out, make sure it is
connected and/or enabled
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
1. If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test. See "Updating
(flashing) BIOS from a disc" on page 560
3. Go to "Undetermined problems" on page 69
1. Go to "Undetermined problems" on page 69
2. Flash the system and re-test
3. Replace component under function test
1. Diskette drive cable
2. Diskette drive
3. System board
No action
Chapter 7
.
Symptom-to-FRU index
53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents