Toshiba RAS-15EKV-UL Service Manual page 59

Split type
Hide thumbs Also See for RAS-15EKV-UL:
Table of Contents

Advertisement

CAUTION
10-4. Indoor Unit
10-4-1. Installation Location
• A location which provides clearances around the
indoor unit as shown in the diagram in the
"CLEARANCES" section.
A location where there are no obstacles near the
air inlet and outlet.
A location which allows easy installation of the piping
to the outdoor unit.
• A location which allows the front panel to be opened
The indoor unit shall be installed such that the top
of the indoor unit comes to at least 6.6 ft (2 m) height.
Also avoid putting anything on the top of the indoor
unit.
A location that will bear the weight of the unit.
CAUTION
• Direct sunlight on the indoor unit's wireless
receiver should be avoided.
• The microprocessor in the indoor unit should
not be too close to RF noise sources.
(For details, see the owner's manual.)
10-4-2. Cutting a Hole and Mounting the
mounting Plate
Cutting a hole
When installing the refrigerant pipes from the rear.
35
120
180
240
The center of the pipe hole is above
the arrow.
Fig. 10-4-1
After determining the pipe hole position on the
ð
mounting plate (
), drill the pipe hole ∅ 2-9/16 in.
(∅ 65 mm) at a slight downward slant to the outdoor
side.
14/16 in.
(23 mm)
Pipe hole
Ø2-9/16 in. (65 mm)
NOTE :
• When drilling a wall that contains a metal lath,
wire lath or metal plate, be sure to use a pipe hole
brim ring sold separately.
Mounting the mounting plate
To unit out line
240mm
Hook
Pipe hole
Indoor unit
When the installating plate is directly
mounted to the wall
1. To hook up the indoor unit, securely fit the
mounting plate onto the wall by screwing it in the
upper and lower parts.
2. To mount the mounting plate on a concrete wall
with, anchor bolts, drill the anchor bolt holes as
illustrated in the figure shown below.
3. Make sure the mounting plate is leveled.
When installing the mounting plate with a mounting
screw, do not use the anchor bolt holes.
Otherwise, the unit may fall down and result in
personal injury and property damage.
Installation plate
(Keep horizontal direction.)
– 59 –
FILE NO. SVM-13070-2
Anchor bolt holes
Hook
To unit out line
240mm
To unit out line
35mm
To unit out line
120mm
240
180
35
120
0
23
Hook
Thread
Mounting
7
Screw
Weight
Fig. 10-4-2
CAUTION
Anchor bolt
Projection
9/16 in. (15 mm)
or less
Fig. 10-4-3
Pipe hole
Ø2-9/16 in.
(Ø65 mm)
1
Mounting plate