Clearing CD mechanism information / Service information / DC offset error information (Clearing E2PROM data)
Status
While pressing and holding [B.BOOST]
key and [ATT] key, reset-start.
This mode is cancelled by resetting. (The last screen will not be retained.)
Data to be cleared is shown below.
CD mechanism information
Service Information
DC offset error information
Clearing DC offset error detection data (E2PROM data clearing)
Procedure
While pressing and holding [3] key and [6] key, reset-start.
Procedure
Press and hold the [3] and
[6] keys, and reset-start
1
1
2
2
This mode is cancelled by resetting. (The last screen will not be retained.)
TEST MODE
Display
C
D
C
D
I2C communication status display
CD mechanism error log display
Displays CD loading error data
Displays CD EJECT error data
Displays CD time code count error data (missing count)
Displays CD time code count error data (count not updated)
Power ON time display
CD operation time display
CD EJECT times display
PANEL open/close times display
Forced Power OFF information display
DC offset error 1 display (Provides information on whether there is an improper connection or another error)
DC offset error 2 display (Provides information on the number of capacitor leaks)
Entering DC offset error display mode.
Display
d
C
E
R
d
C
O
K
d
C
1
E
R
d
C
1
O
K
d
C
1
O
K
d
C
2
4
d
C
2
0
KDC-135/135CR/136
O
At normal termination
At abnormal termination
Note
Description
When DC offset error is detected (when either one of capacitors is
leaking, or an improper connection or another error is detected)
When DC offset error is not detected (when none of capacitors leak,
no improper connection or other error is detected)
When improper connection or other DC offset errors are detected.
When improper connection or other DC offset errors are not detected.
When detecting improper connection or other DC offset errors, clears
detection data. (Clear E2PROM)
When detecting capacitor leak, provides information on the number
of capacitor leaks. (0~4)
When detecting capacitor leak, clears the number of capacitor leaks.
(Clear E2PROM)
Description
13