Mitsubishi Electric MXZ-8A140VA Technical & Service Manual page 74

Split-type, heat pump air conditioners
Hide thumbs Also See for MXZ-8A140VA:
Table of Contents

Advertisement

SW2 setting
Pipe temperature / Liquid(TH3)
– 40~90
ON
1
2 3 4 5 6
Discharge temperature (TH4)
3~217
ON
1
2 3 4 5 6
Output step of outdoor FAN
ON
0~10
1
2 3 4 5 6
The number of ON / OFF times of
compressor
ON
0~9999
1
2 3 4 5 6
Compressor integrating operation times
0~9999
ON
1
2 3 4 5 6
Compressor operating current
ON
0~50
1
2 3 4 5 6
Compressor operating frequency
0~225
ON
1
2 3 4 5 6
LEV opening pulse
0~500
ON
1
2 3 4 5 6
Error postponement code history (1)
ON
of outdoor unit
1
2 3 4 5 6
Operation mode on error occurring
ON
1
2 3 4 5 6
Display detail
SW1
4
5
6
Indoor unit 1
0
0
0
Indoor unit 2
1
0
0
Indoor unit 3
0
1
0
Indoor unit 4
1
1
0
Indoor unit 5
0
0
1
Indoor unit 6
1
0
1
Indoor unit 7
0
1
1
Indoor unit 8
1
1
1
Explanation for display
– 40~90
(When the coil thermistor detects 0: or below, "–"
and temperature are displayed by turns.)
(Example)
When –10:;
0.5 secs.
3~217
(When the discharge thermistor detects 100: or
more, hundreds digit, tens digit and ones digit are
displayed by turns.)
(Example)
When 105:;
0.5 secs.
0~10
0~9999
(When the number of times is 100 or more,
hundreds digit, tens digit and ones digit are
displayed by turns.)
(Example) When 42500 times (425
0.5 secs.
0~9999
(When it is 100 hours or more, hundreds digit, tens
digit and ones digit are displayed by turns.)
(Example) When 2450 hours (245
0.5 secs.
0~50
wOmit the figures after the decimal fractions.
0~255
(When it is 100Hz or more, hundreds digit, tens
digit and ones digit are displayed by turns.
(Example)
When 125Hz;
0.5 secs.
0~500
(When it is 100 pulse or more, hundreds digit, tens
digit and ones digit are displayed by turns.
(Example)
When 150 pulse;
0.5 secs.
Postponement code display
Blinking: During postponement
Lighting: Cancellation of postponement
"00" is displayed in case of no postponement.
Operation mode of when operation stops due to
error is displayed by setting SW2 like below.
(SW2)
ON
1
2 3 4 5 6
74
0.5secs.
2 secs.
10
0.5secs.
2 secs.
1
05
100 times);
0.5secs.
2 secs.
4
25
10 hours);
0.5secs.
2 secs.
2
45
0.5secs.
2 secs.
1
25
0.5secs.
2 secs.
1
50
Unit
:
:
Step
100 times
10 hours
A
Hz
Pulse
Code
display
Code
display