Log Utilities - Toshiba T2150 series Maintenance Manual

Toshiba t2150 series personal computer
Table of Contents

Advertisement

3.21 Log Utilities

3.21.1
Function Description
This function logs error information generated while a test is in progress and stores the results
in RAM. This function can store data on a floppy disk or output the data to a printer. If the
power switch is turned off, the error information will be lost. The error information is dis-
played in the following order:
1.
Error count (CNT)
2.
Test name (TS-NAME)
3.
Subtest number (TS-NAME)
4.
Pass count (PASS)
5.
Error status (STS)
6.
FDD/HDD or memory address (ADDR)
7.
Write data (WD)
8.
Read data (RD)
9.
HDC status (HSTS)
10.
Error status name ( ERROR STATUS NAME)
3.21.2
Operations
1.
Selecting 5 and pressing Enter in the DIAGNOSTIC MENU logs error informa-
tion into RAM or onto a floppy disk. The error information is displayed in the
following format:
XXXXX ERRORS
CNT TS-NAME PASS STS ADDR
001 FDD 02 0000
001 FDD 01 0000
Pass count
Subtest number
Test name
Error count
[[1:Next,2:Prev,3:Exit,4:Clear,5:Print,6:FD Log Read,7:FD Log Write]]
T2150 Series
WD RD HSTS [STATUS NAME]
103 00001
00 00
180 00001
00 00
Address
Error status
Read data
Write data
FDD - WRITE PROTECTED
FDD - TIME OUT ERROR
HDC status
Error status name
3-47

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents