HEATING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION
OUTDOOR UNIT MODEL NO.
INDOOR COIL MODEL NO.
AIR TEMP.
AIR TEMP.
ENTERING
ENTERING
OUTDOOR
UNIT
60
47
40
30
17
10
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE:
KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
LOW CFM
Air Handler
Coil
AV36
–
AV48
–
MV12B
FC/MC35B
MV12B
FC/MC42B
MV16C
FC/MC48C
MV12D
FC/MC48D
Continued on Page 52.
Johnson Controls Unitary Products
YZE03611
FC/MC/PC48C + MV16C
INDOOR
MBTUH
COIL
60
27.9
70
26.6
80
25.4
60
25.4
70
23.7
80
22.0
60
21.7
70
20.8
80
19.9
60
19.9
70
18.6
80
17.2
60
15.0
70
14.3
80
13.5
60
13.6
70
12.7
80
11.7
MBH
KW
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
750
KW
C.O.P.
MBTUH
1.8
4.6
28.2
2.0
3.9
27.0
2.2
3.3
25.9
1.7
4.3
24.8
2.0
3.5
23.6
2.2
2.9
22.4
1.7
3.7
21.9
1.9
3.2
21.1
2.2
2.7
20.3
1.7
3.5
19.4
1.9
2.9
18.3
2.1
2.4
17.2
1.7
2.6
15.0
1.9
2.2
14.3
2.1
1.9
13.6
1.7
2.4
13.5
1.9
2.0
12.6
2.1
1.7
11.8
COP
1.00
1.00
1.00
1.00
1.00
1.00
ID CFM
800
KW
C.O.P.
MBTUH
1.7
4.8
28.5
2.0
4.1
27.4
2.2
3.5
26.4
1.7
4.3
24.3
1.9
3.6
23.5
2.1
3.1
22.7
1.7
3.8
22.1
1.9
3.3
21.4
2.1
2.8
20.7
1.7
3.4
18.9
1.9
2.9
18.1
2.1
2.4
17.3
1.6
2.7
15.1
1.9
2.3
14.4
2.1
1.9
13.7
1.6
2.4
13.4
1.8
2.0
12.6
2.0
1.7
11.8
246750-YTG-M-0908
850
KW
C.O.P.
1.7
5.0
1.9
4.2
2.1
3.6
1.6
4.3
1.9
3.7
2.1
3.2
1.6
4.0
1.9
3.4
2.1
2.9
1.7
3.3
1.9
2.8
2.0
2.5
1.6
2.7
1.8
2.3
2.0
2.0
1.6
2.5
1.8
2.0
2.0
1.7
51