Model 7000 Flow Through Humidifier
12
The HUMIDISENSE Humidistat can also be operated in
automatic mode.
In automatic mode the above setting
adjustments are done automatically for you. You will only have
to adjust your humidistat once based on the table below (also
printed on humidistat label)
AUTOMATIC OPERATION HUMIDITY LEVELS
Dial
- 20˚C /0˚F
-25˚C /-10˚F
Setting
1
10%
10%
2
10%
10%
3
10%
15%
4
15%
20%
5
20%
25%
6
25%
30%
7
30%
35%
If condensation begins to form on your windows or walls for
extended periods of time structural damage may occur. If you
are experiencing this reduce your setting by 5% (in manual
mode),1 dial setting in automatic mode. After each reduction
allow 6 hours for equilibrium to be reached before readjustment.
If the condition persists even after adjusting setting turn off the
humidifier and consult an HVAC professional.
When your home is unoccupied for longer than 3 days during the
winter months, always set the humidistat down to the lowest
setting so that severe weather during your absence will not result
in condensation which might damage your home.
BYPASS AIR ADJUSTMENT, SUMMER SHUT DOWN, AND
YEARLY MAINTENANCE.
Bypass Air Adjustment
Sometimes there can be a static pressure differential that may
cause an excess of air to flow through the bypass tube, causing
less airflow through the distant heat outlets in the house. It may
also blow water off the evaporator pad. In either case the air
damper installed with the bypass collar should be gradually
closed until the condition is corrected. To close the damper
loosen the top screw and lift up on the damper and turn closed
to the desired position. Damper adjustment is another way of
adjusting the amount of humidity being added to the house (the
less air bypassed the less humidity that will be added.)
SUMMER SHUT DOWN
At the end of the heating season complete the following steps.
1. Turn the humidistat off.
2. Unplug the transformer.
3. Close off the water supply at the saddle valve.
4. Close the bypass damper.
-5˚C /20˚F
-10˚C /10˚F
0˚C /30˚F
10%
15%
20%
15%
20%
25%
20%
25%
30%
25%
30%
35%
30%
35%
40%
35%
40%
45%
40%
45%
45%
YEARLY MAINTENANCE AND WINTER START UP
For detailed recommended maintenance schedule refer to the
Maintenance and trouble shooting guide.
At the beginning of the heating season complete the following
steps.
1. Inspect the water supply tube, water drainage tube, and
5˚C /40˚F
Electrical wiring, replace if necessary.
25%
2. Plug in the transformer.
30%
3. Turn on the water supply at the saddle valve and check for and
35%
repair any leaks.
40%
4. Open the bypass damper.
45%
45%
45%