Air King 7000 EC Installation, Warranty, Maintenance, Troubleshooting Manual

Flow-through furnace humidifier

Advertisement

Quick Links

Advertisement

loading

Summary of Contents for Air King 7000 EC

  • Page 2: Installation

    Installation READ COMPLETE INSTALLATION INSTALLATION INSTRUCTIONS AND TEMPLATE STEP #1: RIGHT HAND DUCTING BEFORE STARTING OR LEFT HAND DUCTING Depending on your furnace or for convenience of your Attention Installer: i n s t a l l a t i o n i t m a y b e n e c e s s a r y t o c o n v e r t t h e •...
  • Page 3 Installation 5. Mount the humidifier cabinet on the duct. The two 1. Drill four 2.5 mm diameter holes on the template positioning tabs on the back of the cabinet should used for mounting humidistat. align with the 7/32” holes drilled earlier. Use four 2.
  • Page 4: Warranty

    Warranty • Maintenance WARRANTY top of the distribution tray, it is press fit in place. 4. Remove the distribution tray two hooks at the top of the unit secure it in The manufacturer guarantees the for the period of one year from the place.
  • Page 5 Maintenance pointy object (ie nail) carefully remove the inlet filter. is located in the inlet of the flexible water supply tube remove in step 4. Remove and discard old fitting and replace with a new one. (refer 5. The inlet filter should be fairly clean and free of debris. to the orifice fitting replacement regards installation) 6.
  • Page 6 Maintenance leaks occur you can tighten later to fix them. Figure 4. 9. Replace the bypass tube on the humidifier’s side and secure with spring clamp. Orifice Orifice 10. Turn on the power to the humidifier, Turn on the water supply to the humidifier, Turn on your furnace.
  • Page 7 Maintenance 2004/2005 PRODUCTION MODEL 7000 EC ITEM NUMBER DESCRIPTION QTY/UNIT PART NUMBER humidifier control 1/per 011198000 connection cable 1/per 011175000 base 18 gallon 1/per 011235000 air damper 1/per 01A170930 collar 1/per 01A172107 evaporator pad 18 gallon 1/per 011334000 water distribution tray 1/per 010911002 nozzle...
  • Page 8: Troubleshooting Guide

    Troubleshooting TROUBLE SHOOTING GUIDE • Check the amount of water being supplied to the evaporator pad. (Procedure in Maintenance Guide) PROBLEM: NOT ENOUGH HUMIDITY • Check that the water inlet filter is not plugged. Replace if required. (Procedure in Maintenance Guide) •...
  • Page 9 Troubleshooting • Furnace filter is dirty and needs replacement. POSSIBLE CAUSE: The air going through the unit is not hot enough. For this unit to work it must sense a 4°C • Bypass tube and humidifier not installed parallel, use hard temperature rise over 1 minute of time and the air ducting –...
  • Page 10 Troubleshooting REMEDY: POSSIBLE CAUSE: The unit is not plugged in. • Adjust bypass damper to fully open position. REMEDY: Plug in the unit. • Ensure the bypass tube is fully stretched out tight. POSSIBLE CAUSE: The furnace is not in heating mode. •...
  • Page 11 Troubleshooting POSSIBLE CAUSE: Secondary humidity sources. POSSIBLE CAUSE: Evaporator pad assembly is not installed correctly. REMEDY: Humidity levels vary greatly from home to home – the time of year your home was built will affect the levels – the REMEDY: Check pad and install correctly. amount of showers taken, cooking, the amount of ventilation a home has, as well the amount of people living in a home will POSSIBLE CAUSE: Air Flow through the unit is too great and...
  • Page 13 MODEL AK5000 AK5500 & AK7000 SUPPLEMENTAL INSTRUCTION SHEET WARNING: THIS UNIT IS INTENDED TO BE INSTALLED BY AN LICENCED HVAC PROFESSIONAL – FOR THIS UNIT TO OPERATE PROPERLY THE SUPPLIED 24 VOLT TRANSFORMER MUST BE INTERLOCKED WITH THE FURNACE HEATING CYCLE – THE 24 VOLT TRANSFORMER SHOULD BE ENERGIZED ONLY WHEN THE FURNACE IS IN HEATING CYCLE.
  • Page 14 FEUILLE D’INSTRUCTION COMPLÉMENTAIRE, MODÈLES AK5000, AK5500 ET AK7000 MISE EN GARDE : CET APPAREIL EST CONÇU POUR ÊTRE INSTALLÉ PAR UN PROFESSIONNEL CVC AUTORISÉ SOUS LICENCE – POUR QUE CET APPAREIL FONCTIONNE CONVENABLEMENT, LE TRANSFORMATEUR DE 24 VOLTS FOURNI DOIT ÊTRE INTERVERROUILLÉ AVEC LE CYCLE DE CHAUFFAGE DE LA FOURNAISE - LE TRANSFORMATEUR DE 24 VOLTS DEVRAIT ÊTRE MIS SOUS TENSION SEULEMENT LORSQUE LA FOURNAISE SE TROUVE DANS LE CYCLE DE CHAUFFAGE.