Air King AK7000 Installation, Warranty, Maintenance, Troubleshooting Manual

Flow-through furnace humidifier

Advertisement

Quick Links

Advertisement

loading

Summary of Contents for Air King AK7000

  • Page 2: Installation

    5. The bypass inlet opening should be at least 6” above any restrictions (e.g . the air conditioning coils) inside the duct. 6. The humidifier and bypass collar are at the same level. 7. Take the most direct route to join humidifier and bypass collar.
  • Page 3 5. Mount the humidifier cabinet on the duct. The two positioning tabs on the back of the cabinet should align with the 7/32” holes drilled earlier. Use four supplied screws to secure the cabinet to the duct. 6. Use level to make sure the cabinet is installed correctly.
  • Page 4: Warranty

    Depending on the condition of your water you may want to consider more frequent replacement. 1. Turn off the power to the humidifier, Turn off the water supply to the humidifier, Turn off your furnace.
  • Page 5 9. Reconnect the bypass tube onto the humidifier side and secure in place with the 6” spring clamp. 10. Turn on the power to the humidifier, Turn on the water supply to the humidifier, Turn on your furnace. 11. Run the humidifier and check for and repair any leaks.
  • Page 6 9. Replace the bypass tube on the humidifier’s side and secure with spring clamp. 10. Turn on the power to the humidifier, Turn on the water supply to the humidifier, Turn on your furnace. Run the humidifier and check for and repair any leaks.
  • Page 7 MODEL 7000 EC ITEM NUMBER humidifier control evaporator pad 18 gallon water distribution tray out door air sensor 120/24VAC transformer flex water tube 1/4"x24" needle valve assembly flow through cover 18 gallon side flow through 18 gallon brass compression nut...
  • Page 8: Troubleshooting Guide

    • Check that the unit is level and that the evaporator pad assembly is getting evenly wet. • Check that there is water getting to the humidifier, turn off the water disconnect the water supply to the unit and turn the water back on.
  • Page 9 – use hard ducting for any elbows – take the most direct route when ducting. • The bypass tube or humidifier is installed in front of air- conditioning coils or is blocked in some other way – move to another location and ensure maximum air flow.
  • Page 10 – use hard ducting for any elbows – take the most direct route when ducting. • The bypass tube or humidifier is installed in front of air- conditioning coils or is blocked in some other way – move to another location and ensure maximum air flow.
  • Page 11 REMEDY: Tighten the screws. POSSIBLE CAUSE: The humidifier body is not secured to the furnace duct properly. REMEDY: Ensure all 4 screws which hold the humidifier body in place are installed and are tightened. POSSIBLE CAUSE: Using a copper water supply tube.
  • Page 13 This control is not supplied with the contractor model AK7000, in its place your unit has been provided with a standard mechanical humidistat design for either duct mount or wall mount installation. Refer to the provided humidistat installation sheet for installation instructions.
  • Page 14 à la commande d’humidistat électronique avec fonctionnement manuel et automatique. Cette commande n’est pas fournie avec le modèle AK7000 de l’entrepreneur, et à sa place votre système a reçu un concept d’humidistat mécanique standard pour installation à montage sur canalisation ou mural. Référez-vous à la feuille d’installation de l’humidistat pour les instructions d’installation.