Download Print this page

Ic Pin Function Description - Sony CDX-600 Service Manual

Hide thumbs Also See for CDX-600:

Advertisement

7-8. IC PIN FUNCTION DESCRIPTION

• MAIN BOARD IC302 CXP84124-080Q (SYSTEM CONTROLLER)
Pin No.
Pin Name
1
LIM.SW
2
BUSON
3
EJECT
4
LOAD1
5
LOAD2
6
A.MUTE
7
EMPH
8
CH.R
9
CH.F
10
11
ELV.R
12
ELV.ON
13
CD RST
14
CDON
15 to 23
24
AUTO ON/OFF
25 to 29
30
RESET
31
EXTAL
32
XTAL
33
VSS
34
TX
35
TEX
36
AVSS
37
AVREF
38
ATRIBT
39
MCK
40
EHS
41 to 47
48
SCK
49
SI
50
SO
51
SQCLK
52
SUBQ
53
54
55
MGLK
I/O
Sled limit in detect switch (SW1) input terminal
I
"L": When the optical pick-up is inner position
I
Bus on/off control signal input from the SONY bus interface (IC204) "H": bus on
I
Eject switch (SW303) input terminal "H" active
Save end detect switch (SW12) input terminal
I
"L": When completion of the disc chucking operation
Chucking end detect switch (SW11) input terminal
I
"L": When completion of the disc chucking operation
O
Audio line muting on/off control signal output terminal "H": muting on
O
Emphasis mode output to the D/A converter (IC401) "L": emphasis on
Motor drive signal (save direction) output to the chucking motor drive (IC52)
O
"H" active *1
Motor drive signal (load chucking direction) output to the chucking motor drive (IC52)
O
"H" active *1
O
Not used (open)
Motor drive signal (elevator down direction) output to the elevator motor drive (IC301)
O
"L" active *2
O
Mechanism deck section power supply on/off control signal output "H": power on
O
System reset signal output to the CXA1992BR (IC11) and CXD2530Q (IC101) "L": reset
O
D/A converter and servo section power supply on/off control signal output "H": power on
O
Not used (open)
Setting terminal for the automatic adjustment
I
"L": automatic adjustment, "H": manual adjustment (fixed at "L" in this set)
O
Not used (open)
System reset signal input from the reset signal generator (IC202) and SONY bus interface (IC204)
I
"L": reset
For several hundreds msec. after the power supply rises, "L" is input, then it changes to "H"
I
Main system clock input terminal (8 MHz)
O
Main system clock output terminal (8 MHz)
Ground terminal
O
Sub system clock output terminal Not used (open)
I
Sub system clock input terminal Not used (fixed at "L")
Ground terminal (for A/D converter)
I
Reference voltage (+5V) input terminal (for A/D converter)
I
Selection input of the custom file, D-BASS, etc.
Input of signal for the fine adjustment (linear position sensor adjustment; RV301) of elevator
I
position (A/D input)
I
Elevator height position detect input from the RV302 (elevator height sensor) (A/D input)
O
Not used (open)
I
Serial data transfer clock signal input from the SONY bus interface (IC204)
I
Serial data input from the SONY bus interface (IC204)
O
Serial data output to the SONY bus interface (IC204)
O
Subcode Q data reading clock signal output to the CXD2530Q (IC101)
I
Subcode Q data input from the CXD2530Q (IC101)
O
Not used (open)
I
Not used (fixed at "H")
Magazine eject operation completion detect switch (SW301) input terminal
I
"L": eject completed
Function
– 34 –

Advertisement

loading

This manual is also suitable for:

Cdx-606Cdx-626