Page 1
All clearance requirements are the same for gas as it is for wood burning. Do not burn wood in a Magnum ZC that has been changed over to gas unless the gas log kit has been removed by a professional service man trained to work on the Magnum ZC appliance.
Page 2
Magnum ZC to make sure that the carpet etc does not get dirty vacuum out the entire firebox to get rid of ash and smoke buildup take out the bottom and side firebrick and put them in a box for storage in case the homeowner wants to have the unit changed back to wood at some time in the future.
Page 3
3 ½” back from the front door flange. Drill these holes only through the inner firebox, not through the combustion air pan. Take the SP-40-ZC gas log kit out of the box and Gas Line access to burner check to make sure that all of the parts are enclosed.
Page 4
Make sure that the inlet pressure is reduced to the correct pressure before hooking up the gas line to the valve. ( see the instructions included with the SP-40-ZC log set. ) Attach the pilot assembly to the gas pan on the right side using the screws provided. Make sure that the pilot and igniter assembly is in the correct position.
Page 5
Run the gas log for 30 minutes or more to make sure that all operations are working properly. Go over the operation instructions with the customer to assure that they understand the system. Front of unit Gas log placement SP-40-ZC Gas Log Assembly Fig. 6...