Transporting and Storing LP Gas
Transport only one cylinder at a time. Ensure the cylinder is secured in an upright
position with the control valve turned off and the dust cap in place. Be sure to store
cylinders outdoors and out of the reach of children. Do not store cylinders in a building,
garage, or any other enclosed area.
Leak Testing
All gas piping and connections must be tested for leaks after installation or service. All
leaks must be corrected immediately. Remember, before exchanging an empty bottle for
a new one; make sure all control valves are in the "off" position.
Open the valve (shut-off or 'ON' LP tank).
Apply liquid soap solution to all joints.
Bubbles forming indicate gas leak.
NEVER USE AN OPEN FLAME TO CHECK FOR LEAKS.