Uninterruptible Power Supply
ERA LED 1.5
ERA LED 2.0
ERA LED 2.6
User's manual

Advertisement

Table of Contents
loading

Summary of Contents for Technoware ERA LED 1.5

  • Page 1 Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6 User’s manual...
  • Page 3: Table Of Contents

    No part of this manual may be reproduced, even partially, without the authorisation of TECNOWARE s.r.l. TECNOWARE s.r.l. reserves the right to change specifications at any time and without notice. UPS ERA LED 1.5 – 2-0 – 2.6 User’s manual...
  • Page 4: Safety Warnings

    Install the UPS indoors, in a protected, clean and moisture-free environment. Do not expose to the direct sun light. Do not keep liquids, flammable gases or corrosive substances near the UPS. User’s manual UPS ERA LED 1.5 – 2-0 – 2.6...
  • Page 5: Introduction

    • ERA LED 1.5 (1.5 KVA) • ERA LED 2.0 (2.0 KVA) • ERA LED 2.6 (2.6 KVA) In this manual ERA LED will simply be referred to as UPS. UPS ERA LED 1.5 – 2-0 – 2.6 User’s manual...
  • Page 6: General Characteristics

    Do not keep liquids, flammable gases or corrosive substances near the unit. • Install the UPS on a properly tiled floor. Avoid the installation on a floor that is not tiled flat. • User’s manual UPS ERA LED 1.5 – 2-0 – 2.6...
  • Page 7: External Description

    3 Leds that show the functioning modes, alarm and fault conditions. ON/OFF button: enables the user to turn ON/OFF the UPS. Figure 1 – Front panel UPS ERA LED 1.5 – 2-0 – 2.6 User’s manual...
  • Page 8: Leds And On/Off Button

    3. Fault LED: this FAULT led (red) switches on to indicate the excessive or the OVERLOAD condition or generic “FAULT”. 4. ON/OFF Button: to turn ON and OFF the UPS. User’s manual UPS ERA LED 1.5 – 2-0 – 2.6...
  • Page 9: Rear Side

    Grounded AC Input power socket: IEC C14 type; to connect the UPS to the AC utility line. Input fuse: electrical specification: max current 10 A (ERA LED 1.5 – 2-0 -2.6), voltage 250 V. Grounded UPS Output receptacles: IEC C13 type, black colour, to supply critical loads.
  • Page 10: Electrical Installation And First Start Up

    TECNOWARE. TECNOWARE declines any responsibility if this warning is disregarded. Disregard for these warnings may lead to a risk of electric shock to operators. User’s manual UPS ERA LED 1.5 – 2-0 – 2.6...
  • Page 11: Functioning

    After a complete discharge, the UPS needs 4 hours to recharge completely the batteries. The UPS recharges batteries automatically if it works in Normal mode or if it is off and connected to the AC Input Line. UPS ERA LED 1.5 – 2-0 – 2.6 User’s manual...
  • Page 12: Load Control

    The USB signal is isolated through photo-couplers from the dangerous voltages that are present inside the UPS. Connecting to the Web site www.tecnoware.com, it is possible to download, free of charge, the update UPS management Software TecnoManager, compatible with the most popular Operative Systems. User’s manual UPS ERA LED 1.5 – 2-0 – 2.6...
  • Page 13: Technical Characteristics

    13 x 18,2 x 32 cm Net Weight 7,8 Kg 8,6 Kg 10,4 Kg Technical data may change without prior notice (*) Connect the printers to the ONLY FILTERED Output sockets UPS ERA LED 1.5 – 2-0 – 2.6 User’s manual...
  • Page 14: Maintenance

    Disconnect the battery wires and gently extract batteries from the case. The new batteries must be exactly the same type as the original one. Put inside the new batteries and connect them as the original one. Reassemble the case cover. User’s manual UPS ERA LED 1.5 – 2-0 – 2.6...
  • Page 15: Operator Safety

    After it will be necessary to refer to qualified technical personnel. Original safety characteristics might not be if, for example, the UPS has visible damage or irregular operation. UPS ERA LED 1.5 – 2-0 – 2.6 User’s manual...
  • Page 16: Troubleshooting

    Install correctly the specific Software for your Computer’s Operative correctly installed System. If the described anomalies should continue despite the advised troubleshooting, or should they manifest in any other form, please contact: TECNOWARE SERVICE www.tecnoware.com User’s manual UPS ERA LED 1.5 – 2-0 – 2.6...
  • Page 17: Conformity To The European Directives

    The batteries cannot be disposed as an urban waste, but must be treated in conformity with 2006/66/CE European Directive; any violation is indictable with financial sanctions as established into 2006/66/CE European Directive. UPS ERA LED 1.5 – 2-0 – 2.6 User’s manual...
  • Page 20 TECNOWARE s.r.l. www.tecnoware.com...

This manual is also suitable for:

Era led 2.0Era led 2.6

Table of Contents