2.4 Contrast Adjustment
Measuring equipment ............Oscilloscope
Input signal ...........................16-step gray scale
Enter the service mode.
Adjust part A of the signal waveform at each test point to the minimum with the
VOLUME +/- button.
1. Enter computer input mode and input a 16-step gray scale signal.
Item No.
Test point
4
5
TP-G1
6
2 Enter AV input mode and input a 16-step gray scale signal.
Item No.
Test point
4
5
TP-G1
6
3. Enter component input mode and input a 16-step gray scale signal (480i signal).
Item No.
Test point
4
5
TP-G1
6
Adjustment
TP-R1
Computer red contrast
Computer green contrast
TP-B1
Computer blue contrast
Adjustment
TP-R1
AV red contrast
AV green contrast
TP-B1
AV blue contrast
Adjustment
TP-R1
Component red contrast
Component green contrast
TP-B1
Component blue contrast
A
Fig. 3-4
3-11
Part 3: Adjustment