Circuit Protections; Fuse; Temperature Protection Equipment - Canon LV-X2U/D78-5352 Service Manual

Canon power projector lv-x2j d78-5351; lv-s2j d78-5361, multimedia projector lv-x2u d78-5352; lv-s2u d78-5362; lv-x2e d78-5353; lv-s2e d78-5363
Table of Contents

Advertisement

Part 2: Repair Information

3. CIRCUIT PROTECTIONS

This projector is equipped with the following circuit protections.

3.1 Fuse

A fuse is attached to the power supply.
When the LAMP indicator or the READY
indicator is illuminated, the fuse is normal.
Check the fuse as follows:
1. Remove the power supply unit according
to the servicing procedure.
2. Remove the fuse and check it with a
multimeter.
CAUTION
Fuse
Part No. DY4-5918-000

3.2 Temperature Protection equipment

To protect circuitry and optical components from abnormal rise of the internal
temperature, the following temperature
protections are provided:
1) Thermal Sensor Circuit
If the internal temperature of the projector
rises excessively, the WARNING TEMP.
indicator flashes and the cooling fan starts to
run to cool the projector. When the
temperature becomes normal, the indicator
stops flashing. If it does not stop, unplug the
AC cord from the outlet and check and clean
the air filter. If the indicator still flashes,
inspect the inside (cooling fan, etc.) of the
projector.
The specified fuse should
be used. Using an
unspecified fuse may cause
fire or electric shock.
250V
6.3AAA
Fuse
Thermal switch
(SW902)
2-4
Power supply unit
Fig. 2-2
Reset button
Fig. 2-3

Advertisement

Table of Contents
loading

Table of Contents