8-3 TROUBLESHOOTING
PROBLEM
INDICATED BY
POWER
1. The whole
SOURCE is
DISPLAY
poor.
LED/SEVEN
SEGMENT
DISPLAY is off.
2. DISPLAY LED/
SEVEN
SEGMENT
DISPLAY
operates
abnormally
COOLING is
NO COOLING.
poor.
FREEZER
TEMPERATURE
is incorrect
CHECK
CHECKING METHOD
1. FREEZER/
Check if
REFRIGERATOR.
FREEZER/REFRIGERA
TOR DOOR IS OPEN
and check display.
2. If LAMP is dim.
Check visually.
3. The connection of the
Check connection of
MAIN PWB
CONNECTOR.
CONNECTOR.
1. If the COMPRESSOR
USE TEST MODE1
operate.
(forced COOLING).
If less than 7 minutes
pass after compressor
shuts off, don't press the
KEY and wait.
2. If refrigerant is leaking.
Measure the amount of
frost sticking on
EVAPORATOR and the
surface temperature of
the condenser pipe.
1. If FAN MOTOR
USE TEST MODE1
operates.
(forced COOLING).
2. If DEFROSTING is
Check the amount of frost
normal.
sticking on the
EVAPORATOR .
3. If SENSOR is normal.
of the Refrigerator
SENSOR.
4. Door Line contact.
Check the seal when the
door is closed.
- 35 -
CAUSE
POWER SOURCE is
Use boosting TRANS.
poor.
Applied voltage error.
Reconnect
CONNECTOR.
CONNECTOR
Replace TRANS.
connection is poor.
TRANS FUSE is open.
Replace
COMPRESSOR.
COMPRESSOR locked
Replace OLP, PTC.
or blocked.
OLP, PTC is poor.
Replace MAIN PWB.
COMPRESSOR RELAY
is poor.
THE CONNECTING
Check the connection of
WIRE is poor.
the black wire of the
MAIN PWB
CONNECTOR (CON2).
Refrigerant leakage.
Replace the leaking part
and replace any lost
refrigerant.
FAN MOTOR is poor.
Replace the FAN
MOTOR.
CONNECTING WIRE is
Certify the MOTOR and
poor.
the connection of the
black wire of the MAIN
PWB CONNECTOR
(CON2).
DEFROSTING is poor.
See DEFROSTING is
poor.
SENSOR RESISTANCE
Replace SENSOR.
is poor.
Door liner damaged.
Replace door liner.
SOLUTION