Download Print this page
Intermatic SS7 SERIES Installation And Operating Instructions
Intermatic SS7 SERIES Installation And Operating Instructions

Intermatic SS7 SERIES Installation And Operating Instructions

Advertisement

MODEL SS7 SERIES
INSTALLATION AND OPERATING
INSTRUCTIONS
Features
• Automatic or manual operation. Push the clear cover/switch to switch On or Off at any time.
• Program up to 6 On/Off setting pairs (12 automatic switch settings).
• Each setting time can be once a week, every day, every weekday, or only on weekends.
• LCD Digital clock and readout.
• Random feature automatically varies switching times for a "lived-in" look.
• One AAA Alkaline battery keeps time, operates timer, and keeps the program for up to 1
utility power.
• Can be used for flood (PAR) and compact fluorescent lamps and dimmers.
• Unique "hard contact" output switch allows timer to control most 120 VAC loads.
Also controls many loads 12 to 277 VAC and 12 to 28 Volts DC.
Refer to product label for maximum ratings for various voltages and load types.
Introduction
The timer can replace your regular or 3-way light switch (where two switches control the same light) to control
lights for security, or can control an outlet to switch most 120VAC loads up to the maximum rating on the timer
label. The timer can control incandescent lights, fluorescent lights, flood lights (PAR lamps), stereos, or appliances
such as an air conditioner. The timer can also control many loads 12 to 277 VAC and 12 to 28 Volts DC. Timer
may not be used with lighted switches.
You will need to use a Decorator style wall plate with this timer (not supplied).
The installation instructions on this page are for replacing a light switch (or 3-way light switch) with the timer. See
"Other Installations" on the next page for wiring diagrams for new construction, switching from 3 or more locations,
or using the timer with a dimmer.
Installation Instructions - Single Switch or 3-way - to replace an existing
switch:
1. TURN OFF POWER by REMOVING FUSE or turning
the CIRCUIT BREAKER OFF.
2. Remove the existing wall switch.
Prepare the ends of the building wiring as shown.
BLACK WIRE
BLUE WIRE
RED WIRE
(Capped, Not Connected)
3-way switch: (See "Other Installations" to use a dimmer or if switching from 3 or more locations)
3a. A three way switch has three wires connected to it. One of the wires is "common" (the terminal has a dif-
ferent colored screw or there are markings on the old switch). Connect the Black wire from the timer to the
common wire. Connect the other two wires to the Blue and Red wires from the timer (it doesn't matter which
goes to which.)
WIRE FROM
"COMMON" OF
OLD SWITCH
BLACK WIRE
3b. Identify the "common" terminal at the other (remote 3-way) switch. Connect the supplied jumper wire
from the common terminal to one of the other two terminals of the switch.
(If the light does not turn on when you get to step 9, turn power off at the fuse or circuit breaker and switch
the jumper wire to the other terminal.)
4. Tuck the wires into the wall box leaving room for the timer.
5. Using the screws provided, mount the timer to the wall box then install the wall plate.
Battery (If not supplied with unit.)
6. Release battery holder with flat screw driver at notch (6a) and pull straight out. Uses a standard AAA alkaline
battery. Set the battery in the battery holder (+ towards front of timer). Tuck battery under plastic tab of holder.
Insert battery holder so it clicks into place.
7. Pull at notch at top edge to remove the clear/cover switch so you can use
the programming buttons.
8. To stop the flashing display and turn switch to OFF: Push RESET button;
MAN
AM
Push MODE so CLK is displayed at the upper left; push H+ to stop the
MO
ON
flashing display; push MODE twice so MAN is displayed at the upper
right; push ON/OFF EVENT so display at upper right says OFF (you may
ON/OFF
MODE
RESET
EVENT
hear the timer motor run and a clicking sound).
DAY
H+
M+
9. Your timer is now ready for use. Return the power to the circuit at the
service panel.
Battery
Holder
Battery Replacement
The 1.5 VOLT alkaline battery should operate your timer for 1
or low temperature or frequent use of the manual pushbutton or the 3-way switch will reduce the battery life.
Replace the battery when the digital display is dim, the message 'lobAt' (Meaning LOW BATTERY) is displayed,
or if the timer fails to operate. Press any button to clear the 'lobAt' message. The timer has built-in memory
protection providing at least 15 seconds to change a weak battery without losing your settings. You do not need
to turn off the load or the power in order to replace the battery, however, do not attempt to switch the timer
on or off while the battery is out or your settings will be lost and the timer will need to be reset.
Programming and Operating Instructions
Introduction to Operation and Programming:
The timer is a programmable switch.
At any time you can push the clear cover/switch to manually turn the switch ON or OFF, unless selected mode
is CLK or PGM.
You can program up to 12 ON/OFF EVENTS; times when the timer automatically switches the connected lights
(or other electrical devices) ON or OFF (up to 6 ON events and 6 OFF events). An EVENT can be set to switch
at:
• any specific time, and day of the week,
• a specific time every day,
• a specific time on weekdays, or
• a specific time on weekends.
See Installation Instructions first if your timer is not already installed, or if the AA Alkaline battery is not
installed.
Manual Override
Works like a light switch. Push and release the clear cover/switch
(area over buttons) to switch ON or OFF. Or switch ON and OFF
using the remote switch(es) in multi-switch installations.
CAUTION: This timer should not be used in precision timing applica-
tions where inaccurate timing could have dangerous consequences (i.e., sun
lamps, sauna, etc.)
/
years, even without
1
2
7/16"
Trim building wires bare to 7/16".
Single switch:
3. Connect one of the building wires to the black wire from
the timer, using the twist on wire connectors provided.
Connect the other building wire to the blue wire from
the timer.
THE RED TIMER WIRE IS NOT USED FOR SINGLE
SWITCH INSTALLATIONS. Cap the red wire with a twist
on wire connector. BE SURE THAT ALL THE TWIST ON
WIRE CONNECTORS ARE SECURE.
RED WIRE
COMMON
BLUE WIRE
REMOTE
3-WAY
SWITCH
/
years or more under typical conditions. High
1
2
• Works in AUTO, AUTO RAND or MAN modes.
• You hear a motor/clicking sound.
• ON/OFF display changes.
• The program in AUTO or AUTO RAND remains; it auto-
matically switches ON or OFF at next programmed time.
PUSH ON/OFF
Controls and Displays
Cover/Switch
The clear cover/switch is the manual ON/OFF control.
1. Pull at notch at top edge to remove cover so you can use
the programming buttons.
1
MAN
AM
MO
ON
ON/OFF
MODE
RESET
EVENT
H+
M+
DAY
Push Buttons:
MOVE
JUMPER WIRE
TO OTHER
TERMINAL
IF THIS
SWITCH
DOES NOT
TURN LIGHT
ON
How to set or change the clock
1. Remove the clear cover/switch.
2. Push and release MODE button until CLK is displayed (2a).
3. Push and release DAY button until correct day of week is displayed (3a).
4. Push and release H+ button until hour and AM/PM are correct (4a).
5. Push and release M+ button until minutes are correct (5a).
6. Push and release MODE button to choose AUTO, AUTO RAND or MAN.
7. Replace clear cover/switch.
8. Push and release clear cover/switch to switch load ON or OFF if
necessary.
How to set, change, or review ON/OFF times
1. Remove clear cover/switch.
2. Push and release MODE button until PGM is displayed (2a).
[at event 1
]
on
3. If necessary, push and release ON/OFF/EVENT button until event to set/
change is displayed (3a), or push the ON/OFF/EVENT pushbutton
repeatedly to review all the ON/OFF times.
4. Push and release DAY button until desired day or group of days is displayed
(4a), or push and release the DAY button until "-:--" is displayed, if you
would like to cancel this ON or OFF time.
5. Push and release H+ button until desired event hour and AM/PM are
displayed (5a).
6. Push and release M+ button until desired minutes are displayed (6a).
7. Push and release ON/OFF/EVENT button to choose the next event to set
or change (7a).
8. Push and release MODE button to choose AUTO, AUTO RAND, or
MAN.
9. Replace clear cover/switch.
10. Push and release clear cover/switch to switch load ON or OFF if necessary.
WARNING1 DO NOT USE THE TIMER TO TURN OFF POWER FOR MAINTENANCE (repairs, removing
broken bulbs, etc.). ALWAYS TURN POWER OFF AT THE SERVICE PANEL BY REMOVING A FUSE OR
SWITCHING OFF A CIRCUIT BREAKER BEFORE DOING ANY CIRCUIT REPAIRS.
The 'lobAt' message means the battery is low and needs to be replaced. Uses one standard AAA alkaline battery.
The display is 'noOp' (Meaning no Operation) if the timer fails to operate. This can happen in very cold
temperatures. Normal timer operation should resume at normal temperatures. Press any button to clear the
message(s). If the 'noOp' remains at normal temperatures with a fresh battery, timer needs to be replaced.
To replace cover/switch:
2. Set bottom in first.
3. Click in the top.
To remove battery:
4. Grasp holder at side bumps
(4a,4b) and pull straight out.
4a
To re-install battery:
5. Place battery in holder with "+"
end towards front of timer. Insert
battery and holder into timer.
Push at (5) so it clicks
into place.
Battery Holder
RESET button
Recessed so you don't push it accidentally.
Push and release to reset:
When you press RESET:
• The mode switches to MAN.
• The switch is set to ON.
• The clock is set to MO 12:00 AM and flashes.
• All programmed ON or OFF times are set to null
(at null, no switching occurs, clock displays -:--).
(After pushing RESET, you must set the clock then set the
ON/OFF times.)
• If NoOp appears in display, push battery cover in until you
hear a click. Push reset button to clear display. Proceed
with programming.
MODE button
Push and release to change the mode (upper line of the display).
CLK mode - To set or change the time.
MODE
PGM mode - To set, review or change programmed ON/OFF times.
AUTO mode - Programmed ON/OFF times work. Manual
switching works.
AUTO RAND mode - Programmed ON/OFF times work and
are randomly offset up to 15 minutes. Manual switching works.
MAN mode - Only manual switching works. Programmed
ON/OFF times remain in memory.
The Mode button skips the AUTO modes if the time of day
and/or the ON/OFF times have not been set.
DAY button
Function depends on the mode:
CLK mode - Push and release to cycle through the days of the
DAY
week: MO, TU, WE, TH, FR, SA, SU. Push and hold to cycle quickly.
PGM mode - Push and release to cycle through all week,
weekdays, weekend, individual days of the week and null:
MO TU WE TH FR SA SU (all displayed at once is all week)
MO TU WE TH FR (all displayed at once is weekdays)
SA SU (displayed is weekend)
MO, TU, WE, TH, FR, SA, and SU (are individual days)
-:-- (on clock display is the null setting)
Use null to cancel an unwanted ON or OFF setting. The DAY
button does nothing in AUTO, AUTO RAND or MAN modes.
H+ (hour) button
Works in CLK and PGM modes.
Push and release to cycle forward through the hours of the day.
H+
Push and hold to cycle quickly.
AM and PM automatically switch at 12.
If you pass the correct hour, push and hold to cycle around again.
M+ (minute) button
Works in CLK and PGM modes.
Push and release to cycle forward through the minutes.
M+
Push and hold to cycle quickly.
If you pass the correct minute, push and hold to cycle around
again.
ON/OFF/EVENT button
Function depends on the mode:
CLK mode - ON/OFF EVENT button does nothing.
PGM mode - Switches in order through the 12 programmable
events 1
, 1
, 2
, 2
, 3
on
off
on
off
, 6
, and 6
.
off
on
off
AUTO mode - Manually turns switch on or off.
AUTO RAND mode - Manually turns switch on or off.
MAN mode - Manually turns switch on or off.
3
5a
4a
LOAD MAINTENANCE
Error Messages
3
4b
2
5
, 3
, 4
, 4
, 5
, 5
on
off
on
off
on
2a
5a
4a
3a
2,6
4
5
3a
2a
3, 7
2, 8
4
6
5
6a
7a
(Example)

Advertisement

loading
Need help?

Need help?

Do you have a question about the SS7 SERIES and is the answer not in the manual?

Questions and answers

Summary of Contents for Intermatic SS7 SERIES

  • Page 1 Controls and Displays Cover/Switch The clear cover/switch is the manual ON/OFF control. 1. Pull at notch at top edge to remove cover so you can use MODEL SS7 SERIES the programming buttons. To replace cover/switch: INSTALLATION AND OPERATING 2. Set bottom in first. 3. Click in the top. INSTRUCTIONS To remove battery: 4. Grasp holder at side bumps ON/OFF MODE RESET Features EVENT (4a,4b) and pull straight out. • Automatic or manual operation. Push the clear cover/switch to switch On or Off at any time. • Program up to 6 On/Off setting pairs (12 automatic switch settings). To re-install battery: • Each setting time can be once a week, every day, every weekday, or only on weekends. 5. Place battery in holder with “+” • LCD Digital clock and readout.
  • Page 2: 2/3/4/More Switch Installation

    LIMITED ONE YEAR WARRANTY If within one (1) year from the date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, free of charge. This warranty is extended to the original household purchaser only and is not transferable. This warranty does not apply to: (a) damage to units caused by accident, dropping or abuse in handling, acts of God or any negligent use;...
Save PDF