Mitsubishi Electric MU-GA50VB Service Manual page 35

Split-type, air conditioners wireless type models
Hide thumbs Also See for MU-GA50VB:
Table of Contents

Advertisement

OPERATING PROCEDURE
3. Removing the propeller and the outdoor fan motor
(1) Remove the cabinet. (Refer to 1.)
(2) Remove the propeller nut and the propeller.
NOTE : Loose the propeller in the rotating direction for
removal.
When attaching the propeller, align the mark on the
propeller and the motor shaft cut section.
Set the propeller in position by using the cut on the
shaft and the mark on the propeller.
(3) Remove the clamp of outdoor fan motor lead wire and
disconnect the outdoor fan motor connector.
(4) Remove the screws fixing the outdoor fan motor.
(5) Remove the outdoor fan motor.
4. Removing the compressor
(1) Remove the cabinet. (Refer to 1.)
(2) Remove the relay panel.
(3) Remove the soundproof felt.
(4) Remove the terminal cover on the compressor.
(5) Disconnect lead wires from the compressor.
(6) Recover gas from the refrigerant circuit.
NOTE:
Recover gas from the pipes until the pressure gauge
shows 0 kg/cm
(7) Disconnect the welded part of the discharge pipe.
(8) Disconnect the welded part of the suction pipe.
(9) Remove nuts fixing the compressor.
( 10 ) Remove the compressor.
2
(0MPa).
Photo 5
Propeller
nut
Propeller
Set screws of the outdoor fan motor
Photo 6
Discharge pipe
Suction pipe
Compressor set nuts
35
PHOTOS
Set screws of the
outdoor fan motor
Terminal cover

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mu-ga60vbMu-ga80vb

Table of Contents