Topaz TZ-12B Owner's Manual

Digital thermostat
Hide thumbs Also See for TZ-12B:

Advertisement

1-800-836-7432
Warning!
Improper installation, adjust-
maintenance can cause injury
or property damage. Please
TOPAZ unit.
Avertissement !
installer, régler, réparer ou
entretenir cet appareil peut
lire attentivement les directives
d'installation, d'utilisation et
d'entretien avant de manipuler
l'unité TOPAZ
This manual is the property
of the owner. Leave with the
unit when set-up and start-up
are complete. TEMP-AIR
Inc. reserves the right to
change design and specifica-
tions without prior notice.
P o r t a b l e A i r C o n d i t i o n e r s
Owner's Manual
Models: TZ-12B - TZ-60B4, Digital Thermostat
Unit Specifications .......................................................................................... 2
Rating Information ........................................................................................... 2
Inspection ......................................................................................................... 3
General Description ......................................................................................... 3
Standard Features ..........................................................................................3-4
Optional Features ............................................................................................. 4
Installation Instructions .................................................................................4-5
Unit Operation ..............................................................................................5-6
Preventative Maintenance .............................................................................6-7
Troubleshooting Guide .................................................................................8-9
Installing Replacement Parts ....................................................................10-11
Accessories .................................................................................................... 12
Replacement-Parts List .............................................................................13-14
Wiring Schematic, TZ-12B ........................................................................... 15
Wiring Schematic, TZ-18B ........................................................................... 16
Wiring Schematic, TZ-24B ........................................................................... 17
Wiring Schematic, TZ-36B ........................................................................... 18
Wiring Schematic, TZ-60B ........................................................................... 19
Wiring Schematic, TZ-60B3 ......................................................................... 20
Wiring Schematic, TZ-60B4 ......................................................................... 21
Are you equipped to
handle the heat?

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TZ-12B and is the answer not in the manual?

Questions and answers

Summary of Contents for Topaz TZ-12B

  • Page 1: Table Of Contents

    P o r t a b l e A i r C o n d i t i o n e r s Owner’s Manual Models: TZ-12B - TZ-60B4, Digital Thermostat Unit Specifications ..................2 1-800-836-7432 Rating Information ................... 2 Inspection ......................
  • Page 2: Unit Specifications

    47 x 31 x 64 47 x 31 x 64 Weight, net wt/shipping wt, lb. 221/279 337/375 470/530 713/775 713/775 713/775 1. Rating conditions: 95° F at 60% RH 2. Electrical ratings based on UL 484 TOPAZ Owner’s Manual ™...
  • Page 3: Inspection

    GENERAL DESCRIPTION Digital Temperature Control System Topaz Portable Air Conditioners are designed to spot The digital temperature control system allows the user cool industrial, commercial, institutional and construction to select Cooling or Fan Only operating modes. It also sites.
  • Page 4: Optional Features

    TZ-60B models, and must be piped to ing and file a claim with the delivering carrier within fif- a suitable drain. teen working days. TOPAZ units require minimal instal- Cord Kit (LCDI) (TZ-18B, 24B, 36B) lation. The smaller units (TZ-18B though TZ-36B) can be...
  • Page 5: Cooling Operation

    Portable Air Conditioners 60B3 and TZ-60B4, to insure they are connected in phase level of the pump. with the incoming power. If the unit is not in phase the 5. Attach any required accessories and ductwork. condenser fan and compressor operate in reverse and damage the compressor.
  • Page 6: Ment, Alteration, Service, Or Preventative Maintenance

    Dirt on the blower wheels can TOPAZ air-conditioning units provide high performance be cleaned off with a rag. Dirt should not be a problem if and reliability with a minimum amount of maintenance.
  • Page 7 Portable Air Conditioners porates V-belts drives. The condition of the belt, along with its tension and alignment should be checked at least once a year for proper operation. Replace the belt if it has cracked or is glazed. Adjust the belt tension for a 3/16” deflection of the belt with 2 pounds of force applied at the center of the free span.
  • Page 8: Troubleshooting Guide

    Check for loose or shorted conductors. Secure contact between wires and connectors. Repair or replace as required. Shorted or open run capacitor Replace capacitor. Defective compressor Check for shorts, opens and grounds. Com- pressor replacement should be done by a service technician. TOPAZ Owner’s Manual ™...
  • Page 9 Portable Air Conditioners Problem Cause Remedy Compressor runs but Loose or defective wire Trace and Repair condenser fan does not. Shorted or open condenser motor capacitor. Replace capacitor Insufficient Cooling Bad motor Replace motor Insufficient airflow through evaporator coil due to: - Improper blower rotation (TZ-60B3&4) - Check rotation.
  • Page 10: Read Instructions Before Install-Installing Replacement Parts

    5. Install the hose from the drain pan to the pump inlet. h. Unplug the unit and install the side panels, top 6. Remove the plug from the hole on the side of the unit. panel, filters and screens. TOPAZ Owner’s Manual ™...
  • Page 11: Preventative Maintenance

    Portable Air Conditioners i. Plug the unit into power and test it in all drop to the bottom of the housing. operating modes; COOL and FAN. 7. Remove the motor mount from the motor and install it on the new motor in the same position as the Condenser Fan Motor, previous motor.
  • Page 12: Ing, Operating Or Servicing The Accessories

    14-in evaporator return air plenum, TZ-36B EP-4B 20-in evaporator return-air plenum, TZ-60B, TZ-60B3 and TZ-60B4 DA-10 10-in cold-air supply duct adapter, TZ-18B, TZ-24B, TZ-36B DA-14 14-in cold-air supply duct adapter, TZ-60B, TZ-60B3 and TZ-60B4 CD-60 14-60P plug kit with 6’cord, TZ-60B TOPAZ Owner’s Manual ™...
  • Page 13: Replacement-Parts List

    Portable Air Conditioners Replacement Parts List Description Part Number TZ-12B TZ-18B TZ-24B TZ-36B TZ-60B TZ-60B3 TZ-60B4 • service valve, 3/8-in 88400.249 • • • • • • service valve, 1/2-in 88400.250 • service valve, 5/8-in 88400.251 • service valve, 3/4-in 88400.252...
  • Page 14 Replacement Parts List Description Part Number TZ-12B TZ-18B TZ-24B TZ-36B TZ-60B TZ-60B3 TZ-60B4 • 87300.447 • 87300.416 • delay timer 87900.038 • condensate float relay 86300.018 • condensate float relay base 86300.020 • • • • • • • filter door latch 84900.061...
  • Page 15: Wiring Schematic, Tz-12B

    Portable Air Conditioners Wiring Schematic, TZ-12B...
  • Page 16: Wiring Schematic, Tz-18B

    Wiring Schematic, TZ-18B TOPAZ Owner’s Manual ™...
  • Page 17: Le Fait De Modifier Ou De Mal Wiring Schematic, Tz-24B

    Portable Air Conditioners Wiring Schematic, TZ-24B...
  • Page 18: Wiring Schematic, Tz-36B

    Wiring Schematic, TZ-36B TOPAZ Owner’s Manual ™...
  • Page 19: Entraîner Des Blessures Ou Des Wiring Schematic, Tz-60B

    Portable Air Conditioners Wiring Schematic, TZ-60B...
  • Page 20: Dommages Matériels. On Doit Wiring Schematic, Tz-60B3

    Wiring Schematic, TZ-60B3 TOPAZ Owner’s Manual ™...
  • Page 21: Wiring Schematic, Tz-60B4

    Portable Air Conditioners Wiring Schematic, TZ-60B4...
  • Page 22 TEMP-AIR 3700 West Preserve Boulevard Burnsville, Minnesota 55337-7746 1-800-836-7432 TZ-MAN-BD1 © 2013 TEMP-AIR, Inc. Printed in USA TOPAZ Owner’s Manual ™...