Owner's Manual
P o r t a b l e A i r C o n d i t i o n e r s
Models: TZ-12B & TZ-18B
Unit Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Rating Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
General Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Standard Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Optional Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Unit Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Preventative Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Installing Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Replacement-Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Are you equipped to
handle the heat?

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TZ-12B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Topaz TZ-12B

  • Page 1: Table Of Contents

    Wiring Schematic, TZ-12B &18B ....... .13 servicing the TOPAZ unit.
  • Page 2: Unit Specifications

    Portable ir Conditioners Unit Specifications Rating Information TZ-12B TZ-18B PECIFICATIONS Cooling Capacity, BTU/hr 11,900 17,300 Volts/ph/Hz/amps 115/1/60/15 115/1/60/15 power supply Mechanical Mechanical Thermostat control Metering device TX Valve TX Valve Total power consumption, kW Current consumption, amps 11.9 12.0 15.0 15.0...
  • Page 3: Inspection

    Conditioners is the periodic replacement of the filters and cleaning of the coil surfaces if they become dirty. The TZ-12B and 18B models are equipped with an Both of these items can be accessed by removing the automatic freeze protection control. This control turns inlet grills on the front and back of the unit.
  • Page 4: Optional Features

    Note: The unit will not operate unless the tank is drained periodically. An optional condensate pump is The TZ-12B and 18B models are equipped with a short available for continuous operation. cycle protection timer. The timer provides a five-minute delay before the refrigerant compressor restarts. Under Optional Features normal conditions, no adjustments are necessary.
  • Page 5: Installation Instructions

    To prolong the life of the packaging and file a claim with the delivering carrier unit, perform regular maintenance as described below. within fifteen working days. TOPAZ requires minimal Blower Motors installation. Plug unit in proper NEMA receptacle, and it begins to cool immediately.
  • Page 6 Portable ir Conditioners 5. Check inlet and outlet piping. Clean as necessary. Be sure there are no kinks in the lines that can inhibit flow. 6. Exterior of the unit can be cleaned with a damp cloth. Do not allow water to enter condenser fan outlet or the thermostat.
  • Page 7: Troubleshooting Guide

    Compressor runs, Open fan motor coil circuit Replace fan motor. but fan does not run Shorted or open fan-motor capacitor Replace capacitor. Loose or defective wires Trace and repair. TOPAZ Owner’s Manual ™...
  • Page 8 Portable ir Conditioners Insufficient cooling Insufficient airflow through evaporator See Preventive Maintenance section of this manual. Problem Cause Remedy coil due to: -Dirty air filter in unit -Replace filter. -Dirty evaporator coil -Clean coil with a vacuum cleaner and hose. -Ice on evaporator coil -Defrost.
  • Page 9: Installing Replacement Parts

    4. Connect condensate pump’s power plug to receptacle. 5. Install hose from drain pan to the pump inlet. 6. Remove plug from hole in side of unit. TOPAZ Owner’s Manual ™...
  • Page 10: Accessories

    Portable ir Conditioners Accessories Part Description NK-1 two, 4-in nozzles with attachment kit, TZ-12B NK-2 two, 6-in nozzles with attachment kit, TZ-18B CK-1 10-in ceiling discharge kit, TZ-12B CK-3 14-in ceiling discharge kit, TZ-18B PC-1 condensate pump, 115 volt, TZ-12B and TZ-18B...
  • Page 11: Replacement-Parts List

    Replacement parts List • • Description Part Number TZ-12B TZ-18B • • service valve, 5/16-in 88400.284 • • service valve, 1/2-in 88400.250 • lter drier 83201.043 • expansion valve 88400.477 • 88400.478 • evaporator blower & motor assembly 83100.102 •...
  • Page 12: Wiring Schematic, Tz-12B &18B

    Wiring Schematic, TZ-12B & TZ-18B...
  • Page 13 TEMP-AIR Inc. 3700 West Preserve Boulevard Burnsville, Minnesota 55337-7746 1-800-836-7432 99900.724 © TEMP-AIR, Inc. Printed in USA...

This manual is also suitable for: