Remove the cover from the receiver and Unica HE • using a suitable piece of 2-core flex, connect Linea 28HE*,32HE*,36HE* • the receiver to the Opentherm terminals of Mynute HE • the appliance and refit the PCB cover and Mynute VHE •...
Page 3
To check that the coding is active or has 10-seconds. The LED will illuminate for 3- been successful, go back into the coding seconds before going out. mode for the transmitter (menu > service > coding), when you press OK the LED A 3.0 TRANSMITTER OVERVIEW AND SETUP will light up briefly to confirm that the recei- ver is now paired with the transmitter.
Page 4
Once the batteries have been inserted into plate to the wall at a height of 1.5-metres the battery compartment and the OTR has from the floor. been connected to the boiler, the transmitter can be mounted/located and programmed 3.4 MENUS AND SUB-MENUS for use.
Page 5
See section 5.0 for more detailed informati- 3. The display changes automatically Y e a r to the date setting. on on the SERVICE functions. 2 0 0 2 Set the year, month and date one M o n t h after the other.
If necessary, use the buttons to chan- 3.7 TEMPORARY ADJUSTMENT OF THE ge the display to show COMFORT or TARGET TEMPERATURE LOWER in order to select the preferred temperature regime for the set period. By using the buttons, you can tempora- •...
Page 7
STEP-3: You can confirm time settings via the sub-menu 5.3.3 Checking the temperature profile P3 back to back to no program stored in memory no program stored in memory E m p t y P r o g r a m see 5.3.1 By pressing the OK or By pressing the OK or ▲...
5.0 SERVICE MENU 5.4 CONTROL Using the programming procedure, scroll Characteristics of the PD controller through the main menu until SERVICE is With suitable heating systems the PD con- displayed; press the OK button to select the troller is characterized by a short setting sub menu;...
Offset value adjustable from –3 °C ... +3 °C. Rotary switch position Rotary switch position Setting with ▲ or ▼. Confirm the value with P1, P2 or P3 Display type Display type OK. Cancel with ESC. Time 5.6 OPTIMISATION Target temp. The optimal start function –...
Control lock-in range: 6.0 TIME – DATE – SUMMER/WINTER ± 0.2 K to ± 5 K (PD control) TIME Switching hysteresis: ± 0.2 K to ± 1 0 K See example below (hysteresis control) Memory spaces: 32 temperature changes, programmable for Mo-Fr, 7.0 RESET Sa-Su, each day or for Reset button >...
9.0 MAINTENANCE With the exception of a regular replacement of the batteries for the transmitter, the room thermostats are maintenance-free. Only clean the device with a dry or slightly damp, soft and lint-free cloth. The interior of the device must remain free from water. Replace the two batteries at regular intervals every 1.5 years.
Page 12
Registered address: Vokèra Ltd Borderlake House Unit 7 Riverside Industrial Estate London Colney Herts AL2 1HG enquiries@vokera.co.uk www.vokera.co.uk www.vokera.ie Sales, General Enquires T 0844 391 099 F 0844 391 0998 Vokèra Ireland West Court, Callan Co Kilkenny T 056 7755057 F 056 7755060 Vokèra Limited reserve the right to change...