Input Rectifier Test Points - Lincoln Electric INVERTEC V350-PRO Service Manual

Lincoln electric invertec v350-pro
Hide thumbs Also See for INVERTEC V350-PRO:
Table of Contents

Advertisement

F-23
TEST POINT TERMINALS
+ PROBE
A
B
C
A
B
C
A
B
C
207
207
207
207A
207A
207A
209
209
209
9. If the input rectifier does not meet the
acceptable readings outlined in Table F.2
the component may be faulty. Replace
Note: Before replacing the input rectifier,
check the input power switch and per-
form the Main Switch Board Test. Also
check for leaky or faulty filter capacitors.
10. If the input rectifier is good, be sure to
reconnect leads 207, 207A, and 209 to
the correct terminals and torque to 31
inch lbs. Apply silicone sealant.
TROUBLESHOOTING & REPAIR
INPUT RECTIFIER TEST (CONTINUED)
Table F.2 Input Rectifier Test Points
- PROBE
V350-PRO
Acceptable Meter Readings
207
207
207
207A
207A
207A
209
209
209
A
B
C
A
B
C
A
B
C
11. If the input rectifier is faulty, see the
Input Rectifier Bridge Removal &
Replacement procedure.
12. Replace the case wraparound cover.
ANALOG METER
X10 RANGE
Greater than 1000 ohms
Greater than 1000 ohms
Greater than 1000 ohms
Greater than 1000 ohms
Greater than 1000 ohms
Greater than 1000 ohms
Less than 100 ohms
Less than 100 ohms
Less than 100 ohms
Less than 100 ohms
Less than 100 ohms
Less than 100 ohms
Less than 100 ohms
Less than 100 ohms
Less than 100 ohms
Greater than 1000 ohms
Greater than 1000 ohms
Greater than 1000 ohms
F-23